On the Unusual Fluorescence X-Ray Intensity Variations in Iron-Silicon and Aluminium-Silicon-Copper Alloys
スポンサーリンク
概要
- 論文の詳細を見る
The unusual fluorescence X-ray intensity variations in iron-silicon and aluminium-silicon-copper alloys have been investigated. In these alloys, the unusual behaviour was found not only in the fluorescence X-ray intensity of the Si Kα line but also in that of Fe Kα. It was confirmed that the phenomenon occurred not only when the primary crystals having large differences of the mass-absorption coefficients for the X-ray of the elements to be analyzed precipitated on both sides of the eutectic point and/or the intermetallic compound but also when there was a large difference in the effective volume ratio between the primary phase and the secondary phase. Therefore, the phenomenon should be considered in the fluorescence X-ray analysis of actual samples such as alloys of light metals, ores, oxides, and other compounds.
- 東北大学の論文
著者
-
Hirokawa K.
The Research Institute For Iron Steel And Other Metals
-
GOTO H.
The Research Institute for Iron, Steel and Other Metals
-
SAITO A.
The Research Institute for Iron, Steel and Other Metals
-
MAEDA F.
The Research Institute for Iron, Steel and Other Metals
関連論文
- Polarographic Studies of Some Metal Ions in Fused LiCl-KCl and NaF-KF-LiF Eutectics by Using Improved Molybdenum Microelectrode of Dipping Type
- Polarography of Some Metal Ions in Fused LiCl-KCl-AlCl_3 System with a Dropping Mercury Electrode
- Trennung von Radioisotopen mit Ionenaustauscher-membranen I : Konzentrierung von Y-90 aus einer Sr-90-Y-90 Losung
- Studies on the Determination of Tellurium and Selenium. I : Determinations of Tellurium and Selenium in Presence of Perchloric Acid with Sulfur Dioxide
- Determination of Component in Binary Alloy by Backscattering of Beta Particles
- The Infrared Spectroscopic Study of Metals Intruded into a Silica Framework
- A New Method of Spectrophotometric Determination of Zinc with Alizarin Blue : Application to Estimation of Zinc in Tin and Lead
- Determination of Manganese in Ferromanganese and Chromium in Ferrochromium by X-Ray Fluorescent Spectroscopy
- Spectral Analysis by Low Voltage Impulse Discharge Observation of Spectra by a Time-Resolved Technique and Erosion Rate of Electrodes
- Isolation of the Intermetallic Compounds Al_2Cu, Al_Mg_, Al_3Fe, Al_9Co_2 and Al_3Ni in Binary Aluminium Alloys by Application of an Organic Solvent
- On the Unusual Fluorescence X-Ray Intensity Variations in Iron-Silicon and Aluminium-Silicon-Copper Alloys
- Determination of Impurities in Some Non-Ferrous Metals by Fluorescent X-Ray Spectroscopy
- On the Preparation of Calibration Curves for X-Ray Fluorescent Analysis of Tin-Lead, Antimony-Lead, Antimony-Tin, and Tin-Antimony-Lead Alloy