An Experimental Study of the Microstructures and Mechanical Properties of Swine Cruciate Ligaments(<Special Issue>Bioengineering)
スポンサーリンク
概要
- 論文の詳細を見る
Tensile tests were performed on bone-ligament-bone (BLB) units, sections of ligament, and individual collagen fascicles all from the knees of swine hind legs. A universal testing machine was used for the tensile tests of the BLB units. A specially designed test apparatus was used for the tensile tests of ligament sections and fascicles. The strain values were calculated from the elongation values recorded by a video camera. The results showed that the BLB's stiffness was greatest, followed by the fascicles and the ligament sections. The results are contrary to the popular notion that because the ligament is composed of collagen fascicles in a matrix whose stiffness is almost negligible, the ligament should not be stiffer than the fascicles that compose it. The stiffness might have been caused by mechano-chemical interactions between fascicles and matrix, or contributions from the membranous septum that combines fascicles.
- 一般社団法人日本機械学会の論文
- 2003-12-15
著者
-
Hirokawa Shunji
Department Of Graphic Science Faculty Of Engineering Kyushu University
-
SAKOSHITA Tsutomu
Department of Intelligent Machinery and Systems, Faculty of Engineering, Kyushu University
-
Sakoshita Tsutomu
Department Of Intelligent Machinery And Systems Faculty Of Engineering Kyushu University
-
HIROKAWA Shunji
Department of Arthroplasty, Faculty of Medicine, Saga University
関連論文
- Panoramic Measurement and Analysis of Strain Distribution in the Human ACL Using a Photoelastic Coating Method(Proceedings of the Switzerland-Japan Workshop on New Directions in Cellular and Tissue Biomechanics)(Special Issue on Bioengineering)
- Measurement/Analysis of Deformation and Strain Distribution of the Anterior Cruciate Ligament in the Human Knee
- Three-Dimensional Deformation and Stress Distribution of the Anterior Cruciate Ligament in the Knee : Results of Model Analyses and Visual Simulation
- Bioengineering Research on Frontier Technologies with Nano-, Micro- and Macro-scopic Multiple Viewpoints
- A 3D Kinematic Measurement of Knee Prosthesis Using X-ray Projection Images : Countermeasure to the Overlap between the Tibial and Femoral Silhouettes(Bioengineering)
- An Experimental Study of the Microstructures and Mechanical Properties of Swine Cruciate Ligaments(Bioengineering)
- A 3D Shape Reconstruction of Ligament from Arthroscopic Images
- Kinematic Measurement of Knee Prosthesis from Single-Plane Projection Images(Bioengineering)