After-Pulses in a GM-Counter Caused by Radiations from Radioactive Nuclide
スポンサーリンク
概要
- 論文の詳細を見る
A method of increasing the counts for a random source in an organic-quenched GM-counter is reported. A large increase in counting rate was observed when the wire-potential was lowered succeeding the occurrence of a Geiger-discharge. A distinct peak in counting rate exists against the variation of the wire-potential. Even under such conditions that the great increase is induced, the counting rate is dependent on the intensity of the incident rays. Negative ions are proposed as being the dominant factor in this phenomenon.
- 社団法人応用物理学会の論文
- 1984-03-20
著者
-
成田 裕一
名古屋大学農学部
-
NARITA Yuichi
Department of Physics,Tokyo Metropolitan University
-
Igarashi Ryuji
Department Of Electronic Engineering Akita University
-
Narita Y
Riken Center For Developmental Biology
-
Narita Y
Kyoto Univ. Aichi Jpn
-
Narita Yuichi
Department Of Electronic Engineering Akita University
-
IGARASHI Ryuji
Department of Computer Science and Engineering, Akita University
関連論文
- ロシア共和国西シベリア南部アカデムゴロトク市周辺で採集した小哺乳類のヘリグモソームム科線虫
- New Limits on Neutral Scalar Bosons
- Faunal Survey of Small Mammals in Central Nepal, with Reference to the Distribution of the Genus Soriculus (Insectivora, Mammalia)
- 類人猿におけるペプシノゲン遺伝子の多様性
- 霊長類における胃内タンパク消化酵素ペプシノゲンの多様化
- Gastric digestive proteinases of the greater horseshoe bat, Rhinolophus ferrumequinum
- Pepsinogens and Pepsins from House Musk Shrew, Suncus murinus: Purification, Characterization, Determination of the Amino-Acid Sequences of the Activation Segments, and Analysis of Proteolytic Specificities^1
- Turn-on Detection of Targeted Biochemical Reactions by Triple Resonance NMR Analysis Using Isotope-labeled Probe
- A Method for Increasing the Exoelectron Detection Efficiency using Afterpulses in a Counter : Instruments and Techniques Associated with Exoemission
- A Proposal to Increase the Count Rate of a Discharge-Type UV Detector
- Temperature Dependent Counting Characteristics of an Organic Quenched GM Counter
- After-Pulses in a GM-Counter Caused by Radiations from Radioactive Nuclide
- On the Possibility of Increasing the Detection Efficiency of Exoelectrons by Means of Delayed Pulses in GM Counter
- Pulse Height Distributions of a GM Counter
- On the Increase of the Detection Efficiency of Exoelectrons Using After-Pulses in an Organic-Quenched GM-Counter
- C209 EFFECTS OF INITIAL FLUID-TEMPERATURE ON FREE CONVECTION HEAT TRANSFER IN A STABLY STRATIFIED FLUID BETWEEN VERTICAL PLATES UNDER THE CONDITION OF LATERAL HEATING AT CONSTANT WALL-TEMPERATURE(Double diffusion)
- Multiplicity of pepsinogens in hominoids and adaptation to carnivorous food habits
- Differences in the P1' substrate specificities of pepsin A and chymosin
- ORGANIZATION AND EVOLUTION OF PRIMATE PEPSINOGEN GENES(Biochemistry)(Proceedings of the Seventy-Third Annual Meeting of the Zoological Society of Japan)
- Network Anomaly Detection Based on R/S Pox Diagram
- A Proposal for Real Time Hurst Parameter Derivation
- 1SCP-05 Optically detected magnetic resonance spectroscopy of nitrogen-vacancy centers for subnanoscopic measurement in vivo(1SCP Challenges to in vivo biophysics,Symposium,The 51th Annual Meeting of the Biophysical Society of Japan)