Determination of the Townsend Primary Ionization Coefficient Using a Parallel Plate Avalanche Counter
スポンサーリンク
概要
- 論文の詳細を見る
Gas multiplication factors were obtained from the observed fast pulse of a parallel plate avalanche counter and the Townsend primary ionization coefficients for methane and isobutane were determined from the data over the ranges E/P=150-228 V/cm・Torr and 183-411 V/cm・Torr, respectively. The results for methane agreed well with the values obtained by Heylen.