A mass spectrometer has been designed for the studies on the adsorption of CO, CO_2 and O_2 in a closed system. The spectrometer is a 60° sector type of 10 cm in radius, and made of Pyrex glass. The electrodes are made of gold and silver, and a tin-oxide coating is adopted as the conductive coating. The field emission cathode operated at room temperature is used as the electron emitter of the ion source in stead of a glowing tungsten filament. The above construction is based on the results of the experiments on the activity of O_2 on semi-clean surfaces of the electrode materials. The spectrometer can be operated statically in ultrahigh vacuum of 6×10^<-10> Torr. The static operations for Ar, H_2, N_2 and CH_4 can be made in the best condition, and those for n-C_4H_<10>, CO, CO_2 and O_2, which could not be analyzed statically using a spectrometer with a glowing filament, can be also made in good condition. The detectabilities for the above gases are about 5×10^<-8> cc N.T.P., which are satisfactory for adsorption experiments in a closed system.
- 社団法人応用物理学会の論文
- 1975-04-05
著者
-
Kanomata Ichiro
Department Of Physics Faculty Of Science Tokyo Metropolitan University:central Research Laboratory H
-
Kanomata Ichiro
Department Of Physics Faculity Of Science Tokyo Metropolitan University
-
Irako Mitsuhiro
Department Of Physics Faculty Of Science Tokyo Metropolitan University
-
OGURI Takeo
Department of Physics, Faculity of Science Tokyo Metropolitan University
-
Oguri Takeo
Department Of Physics Faculity Of Science Tokyo Metropolitan University
-
Oguri T.
Faculty of Engineering, Osaka City University
関連論文
- Monte Carlo Study of Ortho-Positronium Laser Cooling
- Low Energy Ion-Neutral Reactions. I. : ^Ne^++^Ne, and Ar^++N_2
- Measurement of Charge-Exchange Probability in He^++He Collision
- Multiple Ionization of Ar and Mg by Electron Impact
- Absolute Measurement of Total Ionization Cross Section of Mg by Electron Impact
- On the Coefficient of Heat Transfer between Gases and Cylinder Walls of the Spark-Ignition Engine
- Studies on Chemisorption of Nitrogen on Molybdenum with the Field Emission Microscope
- Single and Double Ionization of Ca by Electron Impact
- The Static Operation Mass Spectrometer
- Calorimetric Heats of Chemisorption of Nitrogen on Tungsten at Higher Temperatures
- Calorimetric Studies on Chemisorption of Nitrogen on Tantalum
- Angular Distribution of Scattered Electron and Medium Energy Electron Spectroscopy for Metals
- Studies on Chemisorption of Nitrogen on Tungsten with the Field Emission Microscope
- Chemisorption of Nitrogen on Molybdenum
- Hydrostatic Pressure Effects on Self-Trapped Exciton Luminescence in KI
- Studies on Chemisorption of Nitrogen on Tantalum with the Field Emission Microscope
- Monte Carlo Study of Ortho-Positronium Laser Cooling
- Chemisorption of Nitrogen on Tungsten
- Study on Spin Precession of Polarized Slow Positrons in Solids
- Chemisorption and Absorption of Nitrogen with Tantalum