ブリッジの保持力に関する実験的研究
スポンサーリンク
概要
- 論文の詳細を見る
Location of the intermediate abutment, length of span and number of abutments were changed in three-, four- and five-unit fixed partial dentures having two or three abutments and their influences on retentive forces of each abutment were mccasured after repeating load at one-point (the center) and three-points (two more external points) of occluding faces of fixed partial dentures. The results were as follows : 1. When repeating load was applied at the center of five-unit fixed partial dentures having three abutments, the intermediate abutment indicated the lowest retentive forces of all abutments. 2. Location of the intermediate abutment between two external abutments was significant for the retention of each abutment. 3. Fixed partial dentures having two abutments became deflected in proportionally as the span between the abutments became longer. The amount of deflection was significant for theretention of each abutment. 4. Five-unit fixed partial dentures having two abutments indicated the lowest retentive forces of all fixed partial dentures examined. 5. Addition of one more abutment to four-unit fixed partial dentures having two abutments was not always effective in improvement of the retention of fixed partial dentures. 6. Number of loading points was significant for the retention of the fixed partial dentures.
- 日本補綴歯科学会の論文
- 1990-12-01
著者
関連論文
- ブリッジの保持力に関する実験的研究
- 18. 支台築造用コンポジットレジンに関する研究 : 第2報 填塞圧がレジン築造に及ぼす影響について
- 各種歯科材料の疲労に関する研究 : 第1報 合着用セメントおよび支台築造用コンポジットレジンの圧縮強さについて
- 34. 歯学教育へのアイマークレコーダの応用 第1報