線状抽出型オブンによる弗素の微量測定とその応用
スポンサーリンク
概要
- 論文の詳細を見る
A linear wash-out type oven was developed for micro determination of fluoride. The procedures are similar to the Weisz's ring oven technique but with higher sensitivity in detection and with more convenient operations. Organic substances were ashed with an oxygen combustion flask, and the fluoride was detected with alminium chromazrol S complex as the color regent following the recovery from coexisting interferences by the diffusion method. Concentration range from 0.08 to 4×10^5 ppm can be successfully quantitated with 90 per cent recovery, and the standard deviation relative to the expected amount of four repetitive measurements was less than 30 per cent. The method was applied to the fluoride determination in rice crops harvested in localities within 10 kilometers from an alminium refinery firm in Japan. Analytical results showed that the highest concentration was found in bran powder as up to 122 ppm, up to 32 ppm in full grains, and 2.91 ppm as average in cleared grains which is higher than 1.20 ppm as average in the rationed rice grains cleared Clear relations among fluoride concentration in crops and the distance of the harvested location from the alminium refinery discharging hydrogen fluoride were mentioned by the author with 16 rice samples surveyed in 2 years. Fuoride in cleared grain can easily be dissolved in water, and be vaporized and removed from grain on cooking. Average 240 μg of fluoride would be taken into human subject if 1500 g of the polluted rice was served in 3 meals a day, and yet the amount does not exceed the average intake of 180∼240μg among normal adults in rural districts of Japan from rice 3 times a day, daily intake from total diet being estimated as approximately 1.6 to 2.1 mg.
- 社団法人日本産業衛生学会の論文
- 1971-03-20
著者
関連論文
- 43)精神神経科領域におけるCMIの研究(その2) : 深町式神経症判別基準の検討
- 4. 健康管理記録に関するマイクロコンピュータの応用的研究 (健康管理)
- 534. 全身プレチスモグラフと気道抵抗について (公害)
- 72 作業者の適正配置に関する数学的考察
- 251. 慢性アクリロニトリル中毒の実験的研究 (工業中毒(その他の有機物II))
- アクリロニトリル作業者の健康障害に関する疫学的研究
- 5. 学習機能をもつ職業病の電子計算機スクリーニングシステムの設計
- 222. マスクフィルター回収鉛による個人暴露モニタリングの試み (鉛)
- 62. 環境測定のための作業場ゾーニングの考察 (労働条件・労働環境)
- 90. Delves cupを用いた原子吸光法による環境鉛の定量 (鉛)
- 線状抽出型オブンによる弗素の微量測定とその応用
- 411. リングオブンを基礎とした直線抽出型オブンによる微量分析とその農作物特に米中弗化物測定への応用
- 411 リングオブンを基礎とした直線抽出型オブンによる微量分析とその農作物、特に弗化物測定への応用
- 溶媒抽出リングオブン法による空気中金属元素の系統的微量迅速分析
- 067. カスケード・セントリペターによる環境空気の粒径の評価
- 013. ring oven法を応用した尿中鉛の微量半定量分析
- 慢性工業中毒指標としての血清Sialic Acidの評価に関する実験的研究
- 1812 (誌) 慢性工業中毒指標としての血清Sialic Acidの評価に関する実験的研究
- 1602 Ring Oven法による気中金属元素の系統的微量分析
- (誌)慢性工業中毒指標としての血清Sialic Acidの評価に関する実験的研究 : 自由課題 : 中毒(有機非金属)(2)
- Ring Oven法による気中金属元素の系統的微量分析 : 自由課題 : 中毒(金属)(1)