環境水中微量PCDDのポリアミドカラムによる濃縮法
スポンサーリンク
概要
- 論文の詳細を見る
A highly sensitive detection method of PCDDs in environmental water was developed by the concentration method using polyamide columns. PCDDs in water samples were adsorbed first to a polyamide column to which 2-chlorodibenzo-p-dioxin (MCDD) and octachlorodibenzo-p-dioxin (OCDD) were shown to be adsorbed quantitatively. The PCDDs, then, were eluted from the column by ethanol and dichloromethane containing 1% acetic acid. The eluted MCDD and OCDD were analyzed and quantified by GC-MS-SIM with 97% and 98% of recovery, respectively. By this method, the levels of PCDDs were determined in environmental water taken at four points of Tokyo Bay and four points of river flue into Tokyo Bay. The highest PCDDs levels were obtained from the sample of Arakawa River with a level of about 400 pg/liter. The concentration method using polyamide column could be used in routine work since this method enables to quantify efficiently PCDDs even at ppq levels.
- 公益社団法人日本薬学会の論文
- 1993-10-31
著者
関連論文
- Application of Polyamide Column to the Concentration and Fractional Analysis of Some Organic Compounds Responsible for Environmental Water Pollution
- Volatile Halogenated Hydrocarbons in Ambient Air and the Metabolites in Human Urine in an Urban Area
- 環境水中微量PCDDのポリアミドカラムによる濃縮法
- 四塩化炭素投与ラットにおけるその肝内分布と尿中代謝産物
- 四塩化炭素とその代謝物の呼気排泄におけるマウス, ラット間の種差について
- 腸内細菌及び緑膿菌によるニトロソアミンの分解
- 空中浮遊花粉の調査(1982・1983)