Application of Calcein-Loaded Liposomes for the Determination of Membrane Channel Size
スポンサーリンク
概要
- 論文の詳細を見る
We found that calcein-loaded liposomes can be used to evaluate the sizes of channels in membranes by measuring changes in calcein release when the molecular size of the solute added to the outer suspension medium is changed. If the solute added to the outer medium can enter the inner aqueous phase through the channel, the osmotic pressure of the inner phase increases, causing bursting of the liposomes and the release of calcein. Thus, the size of the channel formed in the liposomal membrane can be determined by examining whether the solute added to the outer medium induces calcein release. We used a series of sugars as solutes and estimated the channel size formed by polyene antibiotics. The results agreed well with those conducted in a similar manner using erythrocytes, demonstrating that this method should be useful for examining channel sizes in membranes.
- 社団法人日本薬学会の論文
- 1999-09-15
著者
-
Katsu Takashi
岡山大学 薬
-
Katsu T
Okayama Univ. Okayama Jpn
-
Katsu Takashi
Faculty Of Pharmaceutical Sciences Okayama University
-
Katsu Takashi
Faculty Of Medicine Dentistry And Pharmaceutical Sciences Okayama University
関連論文
- Comparative Study of the Response of Membrane Electrodes Based on Calix[6]arene and Calix[8]arene Derivatives to Organic Ammonium Ions
- Application of Calcein-Loaded Liposomes for the Determination of Membrane Channel Size
- In situ Determination of Phenylpyruvate in Urine Using a Phenylpyruvate-Selective Membrane Electrode Constructed with a Heptyl-4-trifluoroacetylbenzoate Neutral Carrier
- Development of a Portable Cocaine-Selective Electrode (Proceedings of the 22nd Symposium on Toxicology and Environmental Health)
- Development of an Amphetamine-Selective Electrode (Proceedings of the 21st Symposium on Toxicology and Environmental Health)
- Development and Application of a Cocaine-Selective Electrode (Proceedings of the 20th Symposium on Toxicology and Environmental Health)
- Development of Paraquat and Methamphetamine-Sensitive Electrodes and Their Application to Forensic Chemistry (Proceedings of the 18th Symposium on Toxicology, and Environmental Health)
- Structure-Activity Relationship of Polymyxin B Heptapeptide and Analogs
- DIFFERENT MODE OF ACTION OF ALAMETHICIN AND MELITTIN ON ERYTHROCYTE MEMBRANE
- 4α/β-(L/D-Phenylalanylamino)proline Residue-Containing Gramicidin S Analogs with High Antibacterial Activity against Gram-Positive and Negative Bacteria and Low Hemolytic Activity
- Construction of a p-Nitrophenolate-Sensitive Membrane Electrode and Its Application to an Enzyme Assay(Analytical,Chemical)
- Synthesis and Properties of 4α- and 4β-Aminoprolyl Residue-Containing Analogs of Gramicidin S
- ERYTHROCYTE SHAPE CHANGES AND SIMULTANEOUS TETRAETHYLAMMONIUM ION UPTAKE INDUCED BY AMPHIPHILIC COMPOUNDS
- INTERACTION OF HIGHLY BIOACTIVE GRAMICIDIN S ANALOG LACKING HYDROPHILIC AMINO ACID RESIDUES WITH BIOMEMBRANES
- DIFFERENT MODE OF ACTION OF GRAMICIDIN S AND MASTOPARAN ON BIOMEMBRANES
- Potassium-Selective Membrane Electrodes Based on Macrocyclic Metacyclophanes Analogous to Calixarenes
- Dichloromethane-Degrading Properties of Bacteria Isolated from Environmental Water
- Ethylammonium-Selective Membrane Electrode Using p-tert-Butylcalix[6]arene Derivatives
- Discrimination of Methylammonium from Organic Ammonium Ions Using Ion-Selective Electrodes Based on Calix[4]arenecrown-6 Conjugates
- Biogenic Amine-Sensitive Membrane Electrodes Using the Hydrogen Bond-Forming Ability of Solvent Mediators
- Acyclic Neutral Carrier-Based Polymer Membrane Electrode for a Stimulant, Phentermine
- Organic Ammonium Ion-Selective Electrodes Using Acyclic Neutral Carriers Developed for Inorganic Cation-Selective Electrodes
- Potentiometric Determination of NAD(P)H Coenzymes Using a Nitrite-Selective Membrane Electrode and a Nitrate Reductase Enzyme and the Application to Glucose Assay in Human Serum
- Cyclic β-Sheet Antimicrobial Peptides with Environment-sensitive Fluorophores : Photophysical Properties and Molecular Orientation in Lipid Bilayers
- Synthesis and Biological Evaluation of Fluorescent Analogs of Polymyxin B
- Alkyd resin paint as a new membrane material of ion-selective electrode.
- An ESR Study of Methylamino Radicals Photoproduced on the Porous Vycor Glass Surface
- The ESR Spectra of Alkyl Radicals Formed in UV-irradiated Trialkyl Phosphate Glasses
- The Photosensitized Decomposition of Methane Adsorbed on Porous Vycor Glasses Coated with Metal Oxides at 77°K
- NH2 Radicals Trapped on the Surface of Porous Vycor Glass at 77 K