Comparison of the Arcon and the Condylar type articulators on the reproduction of lateral movements : Part III. Articulator adjustment for the lateral movements
スポンサーリンク
概要
- 論文の詳細を見る
It is supposed that on the reproduction of lateral movements, the articulator settings of the Condylar type articulator is different from the condylar pathways of the human jaw. The Arcon type articulator shows the same values as the human jaw. It is not clear, however, about the differences of the articulator settings between the Arcon and the Condylar type articulator. In the present study, the angular differences on each adjustable mechanism are analyzed by reproducing the same lateral movement on the Arcon type articulator; which has all guiding systems on the upper member, and the Condylar type articulator; which has all guiding systems on the lower member. The lateral movement is reproduced on the Arcon type using the mandibular movement cubic model three-dimensionally. The lateral movement of the Condylar type is reproduced by calculating the intercuspal position of the Arcon type relative to the lateral occulusal position of the Arcon type. The differences of the articulator settings between both articulators are calculated and compared. The results are as follows; The angular differences of the articulator settings between the Condylar and the Arcon type articulator are not the same on each adjustable mechanism. The maximal difference of the non-working side condylar guidance is about 4° on the horizontal projective angle and 1° on the sagittal projective angle, while the maximal difference of the working side condylar guidance is about 2° on the horizontal and frontal projective angle. In addition, the changing of the sagittal projective angle on the non-working side condylar guidance affects the articulator settings of the Condylar type articulator. It is necessary to consider the angular differences from the condylar pathways of the human jaw, when evaluating the lateral movement by the Condylar type articulator.
- 日本顎口腔機能学会の論文
- 2005-10-30
著者
-
MIURA Hiroyuki
Fixed Prosthodontics, Department of Restorative Science, Graduate School, Tokyo Medical and Dental U
-
Miura Hiroyuki
Fixed Prosthodontics Department Of Restorative Sciences Division Of Oral Health Sciences Graduate Sc
-
Miura Hiroyuki
Fixed Prosthodontics Department Of Restorative Science Graduate School Tokyo Medical And Dental Univ
-
Hara Shinichi
Dental Office Mitsubishi Electric Corporation
-
Otake Takehiro
Fixed Prosthodontics, Department of Restorative Sciences, Division of Oral Health Sciences, Graduate
-
Tsuruta Jun
Educational Development Section, Department of Health Science Politics, Graduate School, Tokyo Medic
-
Arai Izumi
Division of Electronic Engineering, Institute for Medical and Dental Engineering, Tokyo Medical and
-
Mayanagi Akihiro
Fixed Prosthodontics, Department of Restorative Sciences, Division of Oral Health Sciences, Graduate
-
Hasegawa Shigeo
Fixed Prosthodontics, Department of Restorative Sciences, Division of Oral Health Sciences, Graduate
-
Mayanagi Akihiro
Fixed Prosthodontics Department Of Restorative Sciences Division Of Oral Health Sciences Graduate Sc
-
Hasegawa Shigeo
Dental Office Mitsubishi Electric Corporation
-
Arai Izumi
Division Of Electronic Engineering Institute For Medical And Dental Engineering Tokyo Medical And De
-
Tsuruta Jun
Educational Development Section Department Of Health Science Politics Graduate School Tokyo Medical
-
Otake Takehiro
Fixed Prosthodontics Department Of Restorative Sciences Division Of Oral Health Sciences Graduate Sc
関連論文
- Effect of an internal coating technique on tensile bond strengths of resin cements to zirconia ceramics
- Microtensile Bond Strength of Dual-cure Resin Cement to Root Canal Dentin with Different Curing Strategies
- Effect of reinforcement with resin composite on fracture strength of structurally compromised roots
- Study on the Fracture Strength of Root Reconstructed with Post and Core : Alveolar Bone Resorbed Case
- Photoelastic stress analysis of different post and core restoration methods
- Investigation of distortions around the cervical area of teeth restored with two kinds of crown materials
- Stress Distribution in Roots Restored with Different Types of Post Systems with Composite Resin
- Investigation of Stress Distribution in Roots Restored with Different Crown Materials and Luting Agents
- Analysis of the mechanical properties of food bolus masticated by denture wearers
- Multivariate analysis of the mechanical properties of boluses during mastication with the normal dentitions
- The effects of various finishing materials on the gloss and the color change of indirect prosthetic resin composites.
- Micro-shear Bond Strength of Two All-in-one Adhesive Systems to Unground Fluorosed Enamel
- Accuracy of Temporary Laser Welding of FPDs by Nd:YAG Laser in the Oral Cavity
- The effect of occlusal contacts on adjacent tooth
- Comparison of the Arcon and the Condylar type articulators on the reproduction of lateral movements : Part III. Articulator adjustment for the lateral movements
- Comparison of the Arcon and the Condylar type articulators on the reproduction of lateral movements Part II : Applying the same articulator settings
- Comparison of the Arcon type and the Condylar type articulators on reproduction of lateral movements : Part I: Classification of the articulators in guiding systems
- The Main Occluding Area in Patients with Fixed Partial Dentures
- Comparison of the Main Occluding Area between Adults and Adolescents
- Influence of occlusal height for an implant prosthesis on the periodontal tissues of the antagonist
- Influence of environmental factors on tooth displacement
- The measurement of physiological tooth displacement in function
- The Study of communication behavior of food on buccal and lingual side during mastication
- Influence of the flexural modulus of prefabricated and experimental posts on the fracture strength and failure mode of composite resin cores
- Effect of framework design on the surface strain of zirconia fixed partial dentures
- Effect of thickness of zirconia-ceramic crown frameworks on strength and fracture pattern
- Evaluation of the occlusal contact of crowns fabricated with the bite impression method
- Effect of thickness of zirconia-ceramic crown frameworks on strength and fracture pattern