The purpose of this study was to identify crown materials to decrease the stress concentrated at the cervical area of endodontically treated teeth. To this end, 14 extracted human mandibular premolars were divided into two groups for this study: complete cast crowns versus polymer-based crown and bridge material crowns. Both complete cast crowns (MC) and polymer-based crown and bridge material crowns (HC) were cemented with a glycidyl methacrylate-based resin cement (RC) to composite resin cores with glass fiber posts. Static loading was applied and distortion was measured with four pieces of strain gages attached to the marginal area. Findings showed that there was a large difference in distortion between crown and root in MC. On the other hand, distortions at the cervical area of crown and root were similar in HC.
- 日本歯科理工学会の論文
- 2009-03-01
著者
-
MIURA Hiroyuki
Fixed Prosthodontics, Department of Restorative Science, Graduate School, Tokyo Medical and Dental U
-
Miura Hiroyuki
Fixed Prosthodontics Department Of Restorative Sciences Division Of Oral Health Sciences Graduate Sc
-
Miura Hiroyuki
Fixed Prosthodontics Department Of Restorative Science Graduate School Tokyo Medical And Dental Univ
-
Okada Daizo
Fixed Prosthodontics Department Of Restorative Sciences Graduate School Tokyo Medical And Dental Uni
-
Okada D
Fixed Prosthodontics Department Of Restorative Sciences Division Of Oral Health Sciences Graduate Sc
-
Suzuki Chikako
Fixed Prosthodontics Department Of Restorative Sciences Graduate School Tokyo Medical And Dental Uni
-
KOMADA Wataru
Fixed Prosthodontics, Department of Restorative Sciences, Division of Oral Health Sciences, Graduate
-
Komada Wataru
Fixed Prosthodontics Department Of Restorative Sciences Graduate School Tokyo Medical And Dental Uni
-
YAMAMOTO Masahiro
Fixed Prosthodontics, Department of Restorative Sciences, Division of Oral Health Sciences, Graduate
-
MASUOKA David
Fixed Prosthodontics, Department of Restorative Sciences, Division of Oral Health Sciences, Graduate
-
MIYASAKA Munenaga
Fixed Prosthodontics, Department of Restorative Sciences, Graduate School, Tokyo Medical and Dental
-
Miura Hiroyuki
Fixed Prosthodontics Department Of Restorative Sciences Graduate School Tokyo Medical And Dental Uni
-
Masuoka David
Fixed Prosthodontics Department Of Restorative Sciences Graduate School Tokyo Medical And Dental Uni
-
Miyasaka Munenaga
Fixed Prosthodontics Department Of Restorative Sciences Graduate School Tokyo Medical And Dental Uni
-
Miyasaka Munenaga
Fixed Prosthodontics Department Of Restorative Sciences Division Of Oral Health Sciences Graduate Sc
-
Shin Chiharu
Fixed Prosthodontics Department Of Restorative Science Graduate School Tokyo Medical And Dental Univ
-
Miura H
Fixed Prosthodontics Tokyo Medical And Dental University
-
Okada D
Fixed Prosthodontics Tokyo Medical And Dental University
-
Yamamoto Masahiro
Fixed Prosthodontics Department Of Restorative Sciences Graduate School Tokyo Medical And Dental Uni
-
Okada Daizo
Fixed Prosthodontics Department Of Restorative Sciences Division Of Oral Health Sciences Graduate School Tokyo Medical And Dental University
-
Komada Wataru
Fixed Prosthodontics Department Of Restorative Sciences Division Of Oral Health Sciences Graduate School Tokyo Medical And Dental University
-
Miura Hiroyuki
Fixed Prosthodontics Department Of Restorative Sciences Division Of Oral Health Sciences Graduate School Tokyo Medical And Dental University
関連論文
- Effect of an internal coating technique on tensile bond strengths of resin cements to zirconia ceramics
- Microtensile Bond Strength of Dual-cure Resin Cement to Root Canal Dentin with Different Curing Strategies
- Effect of reinforcement with resin composite on fracture strength of structurally compromised roots
- Study on the Fracture Strength of Root Reconstructed with Post and Core : Alveolar Bone Resorbed Case
- Photoelastic stress analysis of different post and core restoration methods
- Investigation of distortions around the cervical area of teeth restored with two kinds of crown materials
- Stress Distribution in Roots Restored with Different Types of Post Systems with Composite Resin
- Investigation of Stress Distribution in Roots Restored with Different Crown Materials and Luting Agents
- Analysis of the mechanical properties of food bolus masticated by denture wearers
- Multivariate analysis of the mechanical properties of boluses during mastication with the normal dentitions
- The effects of various finishing materials on the gloss and the color change of indirect prosthetic resin composites.
- Micro-shear Bond Strength of Two All-in-one Adhesive Systems to Unground Fluorosed Enamel
- Accuracy of Temporary Laser Welding of FPDs by Nd:YAG Laser in the Oral Cavity
- The effect of occlusal contacts on adjacent tooth
- Comparison of the Arcon and the Condylar type articulators on the reproduction of lateral movements : Part III. Articulator adjustment for the lateral movements
- Comparison of the Arcon and the Condylar type articulators on the reproduction of lateral movements Part II : Applying the same articulator settings
- Comparison of the Arcon type and the Condylar type articulators on reproduction of lateral movements : Part I: Classification of the articulators in guiding systems
- The Main Occluding Area in Patients with Fixed Partial Dentures
- Comparison of the Main Occluding Area between Adults and Adolescents
- Influence of occlusal height for an implant prosthesis on the periodontal tissues of the antagonist
- Influence of environmental factors on tooth displacement
- The measurement of physiological tooth displacement in function
- The Study of communication behavior of food on buccal and lingual side during mastication
- Influence of the flexural modulus of prefabricated and experimental posts on the fracture strength and failure mode of composite resin cores
- Photoelastic Analysis Comparison of Partial and Full Frameworks for Fiber Reinforced Composite FPD
- Effect of framework design on the surface strain of zirconia fixed partial dentures
- Effect of thickness of zirconia-ceramic crown frameworks on strength and fracture pattern
- Evaluation of the occlusal contact of crowns fabricated with the bite impression method
- Effect of thickness of zirconia-ceramic crown frameworks on strength and fracture pattern