大洗工学センターでの運用に向けた個人被ばく管理用線量計に関する性能の調査
スポンサーリンク
概要
- 論文の詳細を見る
An investigation on the performance of various dosimeters to be used for individual monitoring at the O-arai Engineering Center (OEC) was executed. The present TLD system was compared with recently produced dosimeters, such as OSL, Glass dosimeter, EPD and SSTD. The practical use of these dosimeters was also taken into account. There were no problems for any of the dosimeters for γ-ray individual monitoring. The OSL and glass dosimeters, which have good characteristics for γ-ray, can be used in various radiation environments without correction. On the other hand, the conversion factor is needed for low-energy γ-ray dosimetory when using EPD or TLD. None of the individual neutron dosimeters' responses relative to the neutron dose are adequate. Respective dose corrections according to the field conditions should be applied to the dosimeter outputs. The directional dependence of the relative response of EPD and SSTD are significant, and attention should be paid to the directional distribution of incident neutrons when using EPD or SSTD. The operational characteristics of each dosimeter were discussed, such as batch processing availability, robustness, fading characteristic, and reusability. As the result of the investigation, EPD was found to be the best γ-ray individual dosimeter for OEC applications, because of its flexibility in operation. On the other hand, the best neutron dosimeter for OEC is the TLD because of the low directional dependence of response.
- 日本保健物理学会の論文
著者
-
橋本 周
(独)日本原子力研究開発機構大洗研究開発センター安全管理部環境監視線量計測課
-
橋本 周
核燃料サイクル開発機構大洗工学センター安全管理部放射線管理課
-
橋本 義大
核燃料サイクル開発機構大洗工学センター安全管理部
-
石川 正康
核燃料サイクル開発機構大洗工学センター安全管理部
-
江森 修一
核燃料サイクル開発機構大洗工学センター安全管理部
-
橋本 義大
核燃料サイクル開発機構大洗工学センター安全管理部:(現)株式会社セルナック業務部
関連論文
- 公開シンポジウム「UNSCEARの最新動向と放射線防護研究の展望」の論点と感想
- IRPA-10印象記
- 「第3回最近の外部被ばく線量測定・評価に関するワークショップ : 原研中性子標準校正施設の完成を契機に」印象記
- 位置検出型ファイバーエリアモニタの開発
- Scope of Radioactive Waste Management for Large Accelerator Facilities : From the Example of SLAC, Involving Environmental Restoration Project
- 大洗工学センターでの運用に向けた個人被ばく管理用線量計に関する性能の調査