Data Correction in ESR Dosimetry for the Average Absorbed Dose of Teeth Exposed to External Photon
スポンサーリンク
概要
- 論文の詳細を見る
A data-correction technique for the electron spin resonance (ESR) dosimetry was discussed in order to estimate an average absorbed dose of teeth exposed to external photon Fourteen TLDs (thermoluminescent dosimeters) were used in the experiments to obtain the dose distribution in the human mouth Each TLD was installed on the backside of the teeth in a female rando-phantom in order to estimate the absorbed dose of each tooth The rando-phantom was exposed to photon beams of <137>^Cs (066 MeV) and <60>Co (I 2/I 3 MeV) to investigate the influence of the energy on the dose distribution The direction of the photons that hit the surface of the face could also affect the distribution of the dose in the phantom mouth The incident angles of the photon beam were changed at 45-degree intervals around the longitudinal axis of the rando-phantom at the same height as the teeth The largest difference among the measured doses, depending on the position of the teeth and photon energy, was in excess of 40% in the case of the exposure due to the beam direction from the backside of the phantom head at the energy of 662 keV A sample of tooth enamel would be valuable for estimating the effective dose (Sv) calculated from the absorbed dose with ESR dosimetry However, this study shows that the position of a tooth in the mouth affects the estimated value of an average absorbed dose of teeth A simple technique to correct the ESR dosimetric results is suggested in this paper The average absorbed dose of a tooth can be adequately estimated by using a simple formula that takes into consideration the position of the tooth, photon beam direction, and photon energy
- 日本保健物理学会の論文
著者
-
Ishii Kentaro
Science Univeisily Of Tokyo
-
Kosako Toshiso
Research Center For Nuclear Science And Technology The Univeisity Of Tokyo
-
Iimoto Takeshi
Research Center For Nuclear Science And Technology The Univeisity Of Tokyo
-
Kosako T
Univ. Tokyo Tokyo Jpn
関連論文
- Data Correction in ESR Dosimetry for the Average Absorbed Dose of Teeth Exposed to External Photon
- Measurement of Dose Distribution in Mouth for gamma-ray External Exposure
- Theoretical Background of the Dosimetry System 86 (DS86) : I. DOSIMETRY
- Data Analysis System f or Environmental Radiation Monitoring
- Development of Radiation Protection on TENORM
- Sensitization of Solid State Nuclear Track Detector in Carbon Dioxide for Improved Fast Neutron Dosimeter : Monte Carlo Simulation and Experimental Results for Energy Response of Neutron Dosimeter and Quantitative Estimation of Sensitization by CO_2 Pre-e
- Energy Response of an Imaging Plate to Low-energy Photons for Use in Dosimetry
- (1) Scheme for Spent Radiation Source Management : Safe Management of Spent Radiation Source