Experimental result of standard time and frequency signal (STFS) dissemination system via GEO-satellite is described in this paper. We propose the differential mode STFS as the most effective calibration technique for mitigating errors in GEO-satellite based STFS dissemination system. We then use trilateration technique associated with extended Kalman filtering (EKF) to further improve the accuracy of differential mode STFS by improving the accuracy of predicted satellite position. It is found to be possible to track Korean domestic satellite KOREASAT within a few hundred meters accuracy in order to provide a reliable, extremely accurate time service through setting up domestic-only baseline. Our simulation results show that a time accuracy is a few ns and a frequency stability is better than 1 part in 10^<14> for an averaging time of 7 days all over Korean peninsula.
- 社団法人電子情報通信学会の論文
- 2001-10-17
著者
-
Seo Jong
Department of Electrical and Electronic Engineering, Yonsei University
-
Lee K
Department Of Electrical & Electronics Engineering Yonsei University
-
Lee Kee
Department of Electrical & Electronics Engineering, Yonsei University
-
Yoon Jae-Chul
Department of Astronomy, Yonsei University
-
Seo Jong
Department Of Electrical & Electronics Engineering Yonsei University
-
Yoon Jae-chul
Department Of Astronomy Yonsei University
-
Lee Keehoon
Department of Electrical & Electronics Engineering, Yonsei University
-
Seo Jongsoo
Department of Electrical & Electronics Engineering, Yonsei University
関連論文
- Performance of DS-CDM-SQAM in Nonlinear Land Mobile Satellite Broadcasting Environments(Components)
- Broadcasting of Highly Accurate Timing & Frequency Reference via Geostationary KOREASAT
- Chip equalizer using tap selection algorithm for Satellite Digital Multimedia Broadcasting (DMB) (衛星通信)
- Formation Mechanism and Pore Size Control of Light-Emitting Porous Silicorn
- Korean Normative Database for Time Domain Optical Coherence Tomography to Detect Localized Retinal Nerve Fiber Layer Defects (Preliminary Study)
- A Study on Technique for Synchronization Error Calibration of Frequency & Time Signal Dissemination System via GEO-Satellite
- Gas Jet-Enhanced Glow-Discharge Atomic Spectrometry for Direct Solid Analysis
- Incidence and risk factors for radiocontrast-induced nephropathy in patients with hepatocellular carcinoma undergoing transcatheter arterial chemoembolization
- Two CML patients who subsequently developed features of essential thrombocythemia with JAK2-V617F mutation while in complete cytogenetic remission after treatment with imatinib mesylate