コーヌスクローネ支台歯の挙動に関する 3 次元的解析 : 遊離端義歯のデザインの相違による影響
スポンサーリンク
概要
- 論文の詳細を見る
Since the importance of the rigid connection between abutment teeth and retainer was advocated for supporting removable partial denture, the conical crown (Konuskrone) - retained dentures have stood high in the clinical evaluation. However, not a few problems involving falling down of inner crown, increase in abutment tooth mobility and breakage of denture have been reported. The present study was scheduled to experimentally investigate the characteristic behaviors of the abutment teeth for Konuskrone retainers when they were altered in number and location in the mandibular unilateral distal extension removable partial denture. Six types of unilateral distal extension partial dentures were constructed ; three of them were of unilateral designs having one, two and three abutment teeth on the same side of the denture base, respectively, and the other three of bilateral designs having additional one abutment tooth on the opposite side in each of the above unilateral designs. The tooth movement was measured in horizontal, frontal and sagittal planes by means of mandibular kinesiography (MKG) and laser displacement sensors on a Kennedy class II simulation model. The results obtained were as follows : 1. It was found that the abutment teeth movements involved not only simple tipping but also horizontal displacement and gyration of their tooth axes. 2. It was the most difficult to take countermeasures in Konuskrone to deal with the movement against the force from lingual side. 3. In the unilateral design, the primary abutment tooth movement could not be restrained by addition of one mesial abutment while one more mesial addition showed significant reduction in the movement. 4. In the case of the bilateral designs, application of only primary abutment tooth caused large displacement. Addition of one mesial abutment tooth on the denture side was effective for reducing the displacement ; however, one more mesial abutment had a tendency to rather increase the displacement. 5. In comparison of the designs having a given number of the abutment teeth, the bilateral design showed more favorable behavior than the unilateral with two abutment teeth while there was little difference in efficiency between them with three abutment teeth, against all the forces except from lingual side. No effects were found in both the two designs having two or three abutment teeth against the force from lingual side.
- 九州歯科学会の論文
- 1994-02-25
著者
関連論文
- 撤去を余儀なくされたインプラントの 2 症例
- 27. 上顎部分欠損を有する患者に対する補綴的機能回復(第 58 回九州歯科学会総会講演抄録)
- 27 上顎部分欠損を有する患者に対する補綴的機能回復
- 純チタン床義歯の評価
- 顎関節症患者に対する顎運動計測の診断的価値について
- 31. コーヌスクローネ支台の挙動に関する 3 次元的解析 : 荷重点の変化が支台歯の挙動に及ぼす影響(第 54 回九州歯科学会総会講演抄録)
- P∿31 コーヌスクローネ支台の挙動に関する 3 次元的解析 : 荷重点の変化が支台歯の挙動に及ぼす影響
- 磁性アタッチメントのパーシャルデンチャーへの臨床応用 : ノンクラスプパーシャルデンチャーの製作
- 12 顎関節症 IV 型患者に対する保存的療法について
- 12 顎関節症 IV 型患者に対する保存的療法について
- スミプロイデンチャーシステムにより製作したポリカーボネート床義歯の臨床的評価
- 26. 顎関節症患者に対する統一プロトコールの提案と試作プロトコールに関する検討(第 55 回九州歯科学会総会講演抄録)
- 21. チタン床義歯の臨床評価 : 第 1 報 上顎全部床義歯について(第 55 回九州歯科学会総会講演抄録)
- 咀嚼筋および顎関節部の疼痛閾値の定量的計測法
- P∿21 チタン床義歯の臨床評価 : 第 1 報 上顎全部床義歯について
- P∿26 顎関節症患者に対する統一プロトコールの提案と試作プロトコールに関する検討
- 29. パーソナルコンピュータによる患者管理の効率化について(第 54 回九州歯科学会総会講演抄録)
- P∿29 パーソナルコンピュータによる患者管理の効率化について
- 磁性アタッチメントを応用した義歯の維持力に関する実験的研究
- コーヌス冠の維持力に関する基礎的研究 : 第1報 内冠の形態が維持力に及ぼす影響
- 11. コーヌスクローネ支台歯の挙動第 2 報 : 新しい計測方法を用いた各支台歯の挙動解析(第 52 回九州歯科学会総会講演抄録)
- コーヌスクローネ支台歯の挙動に関する 3 次元的解析 : 遊離端義歯のデザインの相違による影響 : 主論文の要旨
- コーヌスクローネ支台歯の挙動に関する 3 次元的解析 : 遊離端義歯のデザインの相違による影響
- 新しく開発された磁性アタッチメントの臨床的評価