Analytical Study of Critical Heat Flux in Two Phase Thermosyphon : Relationship between Maximum Falling Liquid Rate and Critical Heat Flux
スポンサーリンク
概要
- 論文の詳細を見る
An analytical study has been done of critical heat flux of a two-phase thermosyphon, in which a liquid film and a vapor flow exist in a countercurrent annular flow. The CHF point on the thermosyphon is proved to correspond to a maximum falling liquid rate fed to the thermosyphon, which can be determined from three equations of momentum, its partial derivative with void fraction, and mass balance in the thermosyphon. This maximum point, furthermore, becomes identical to the point at which an envelope line generated from momentum equation and its partial derivative, intersects the mass balance line. The CHF calculated from the maximum liquid rate, is found to be in fairly good agreement with the existing CHF data in a closed thermosyphon and the CHF data measured for open themosyphon. Normal operation of the thermosyphon cannot be obtained at any liquid of water, R113, and R22 for a small tube diameter of less than 2 mm within a wide range of L/D-4.8 to 960 and density ratio of ρι/ρG=6.17 to 1602.
- 一般社団法人日本機械学会の論文
- 1996-11-15
著者
-
Kurihara Akikazu
Department Of Mechanical Engineering Faculty Of Science And Engineering Saga University
-
Monde Masanori
Department Of Mechanical Engineering Faculty Of Science And Engineering Saga University
-
Monde Masanori
Department Of Mechanical Engineering
-
Mitsutake Yuhichi
Department of Mechanical Engineering, Faculty of Science and Engineering, Saga University
-
Mihara Shinichi
Department of Mechanical Engineering, Faculty of Science and Engineering, Saga University
-
Mitsutake Yuhichi
Department Of Mechanical Engineering Faculty Of Science And Engineering Saga University
-
Mihara Shinichi
Department Of Mechanical Engineering Faculty Of Science And Engineering Saga University
関連論文
- TED-AJ03-296 TRANSIENT HEAT TRANSFER DURING QUENCHING OF A VERTICAL HOT SURFACE WITH BOTTOM FLOODING
- Analytical Study of Critical Heat Flux in Two Phase Thermosyphon : Relationship between Maximum Falling Liquid Rate and Critical Heat Flux
- Critical Heat Flux in Saturated Forced Convective Boiling with anh Impinging Jet : Coexistence of Pool and Forced Convective Boiling
- Characteristics of Transient Heat Transfer on a Hot Surface during Cooling with Spray
- E213 PRESSURE RECOVERY IN EVACUATED ENCLOSURE AND HEAT TRANSFER DURING TRANSINT COOLING OF HIGH TEMPERATURE SURFACE(Evaporation-2 and others)
- Analysis of Ammonia Vapor Absorption into Ammonia Water Mixtures : Rate of Absorption Reaction
- ESTIMATION OF SURFACE TEMPERATURE AND HEAT FLUX USING INVERSE SOLUTION FOR ONE DIMENSIONAL HEAT CONDUCTION
- Determination of Surface Temperature and Heat Flux Using Inverse Solution for Two Dimensional Heat Conduction
- Homogeneous Boiling Explosion during High Heat Flux Pulse Heating of Water
- Characteristics of Heat Transfer and Wetting Front during Quenching by Jet Impingement