Energy Losses Due to Combination of Flow at Tees
スポンサーリンク
概要
- 論文の詳細を見る
The loss coefficients and the power-loss coefficients for sharp-edged combining tees with the area ratios of 11. 44 and 17. 72 are determined experimentally. Based on the least squares analyses of the experimental results of both the present authors and previous investigators, empirical equations of loss coefficients for combining tees are proposed. The effects of both the area ratio and the radius of curvature of the wall at the joining edge on loss coefficients are taken into account in deriving the equations. The comparison of the proposed equations with the experimental results shows that the proposed equations can be used to reliably estimate the energy losses at combining tees.
- 一般社団法人日本機械学会の論文
- 1996-08-15
著者
-
Oka K
Department Of Oral & Maxillofacial Prosthodontics And Oral Implantology University Of Tokushima
-
OKA Kenji
College of Engineering, Nihon University
-
NOZAKI Takahito
Nippon Denso Co., Ltd.
-
ITO Hidesato
College of Engineering, Nihon University
-
Ito Hidesato
College Of Engineering Nihon University
-
Nozaki Takahito
Nippon Denso Co. Ltd.
関連論文
- Estimation of Residual Stress in Dental Porcelain by Laser-Raman Spectroscopy
- Influence of a Vent Hole on the Retentive Force of a Cement-retained Superstructure before/after Thermocycling
- Energy Losses Due to Combination of Flow at Tees