黒色メンブランフィルターへの不均一な沈殿捕集による硫酸イオンの簡易目視定量
スポンサーリンク
概要
- 論文の詳細を見る
The measurement of sulfate ion is important in environmental and industrial fields. However, a field-analytical method which can be implemented in field testing and performed the site is still lacking. Therefore, the development of a sensitive, yet simple technique is need ed for the field determination of sulfate ion. In this study, a simple visual method has been established for the determination of sulfate ion at PPm levels using a black membrane filter Our method consists of two steps : barium chloride is added to a water sample to form barium sulfate, and the mixture containing the white precipitate is filtrated through a black membrar filter using a 10 ml syringe. We found that the precipitate is effectively concentrated in a distinct pattern on the membrane filter, which is a tracing of the reverse side of the support screen. Sulfate ion as low as 2 ppm concentrations can be visually detected when a 10 ml sample is used. The method reported here will be useful as a simple and rapid field test, which has long been great demand.
- 社団法人日本分析化学会の論文
- 2003-09-05
著者
-
金子 恵美子
東北大学大学院工学研究料応用化学専攻分子システム化学講座応用計測化学分野
-
金子 恵美子
東北大学大学院工学研究科
-
森田 啓介
東北大学大学院工学研究科
-
磯江 準一
独立行政法人科学技術振興機構 研究成果活用プラザ宮城
-
磯江 準一
東北大学大学院工学研究科
関連論文
- オクタデシルシリル化シリカディスクを用いる微量鉛のイオン対抽出/蛍光目視定量