Measurement of Cerebral Blood Flow by Ultrasonic Doppler Technique : Hemodynamic Correlation of Internal Carotid Artery and Vertebral Artery
スポンサーリンク
概要
- 論文の詳細を見る
The hemodynamic correlation of internal carotid artery and vertebral artery before and after intravenous papaverine administration were investigated by using ultrasonic Doppler technique. (1) The blood flow pattern in vertebral artery is prone to be more discontinuous than that in internal carotid artery in the aged independent of blood pressure or cerebral vascular disease. The result suggests that the cerebral vascular resistance in the territory of vertebral artery is more increased than that in internal carotid artery in the aged. As to the mechanism of increased vascular resistance, the atherosclerosis in the territory of vertebral artery is important. (2) The vasodilation in patient with cerebral vascular disease is prone to be more less than that in subject without the disease. The result suggests that the patient with cerebral vascular disease has more tendency to fall into cerebral vascular insufficiency, since the cerebral blood vessel is already near by maximal dilatation, i.e., failure of homeostatic regulation of cerebral circulation.
- 社団法人日本循環器学会の論文
- 1966-08-15
著者
-
Miyazaki Manabu
The Department Of Internal Medicine Kosaiin Hospital Suita City
-
Miyazaki Manabu
The Department Of Internal Medicine Kosaiin Hospital
-
Miyazaki M.
The Department of Internal Medicine of Kosaiin Hospital
関連論文
- Measurement of Cerebral Blood Flow by Ultrasonic Doppler Technique
- Measurement of Cerebral Blood Flow by Ultrasonic Doppler Technique : THEORY
- Measurement of Cerebral Blood Flow by Ultrasonic Doppler Technique : Quantitative Detection of Cerebral Arteriosclerosis
- Measurement of Cerebral Blood Flow by Ultrasonic Doppler Technique Effects of Several Vasodilators on Cerebral Circulation, with Special Reference to Aminophylline, Nicotinic'acid and Papaverine
- Measurement of Cerebral Blood flow by Ultrasonic Doppler Technique : Effects of Low Temperature, Induced Hypertension and Arrhythmia on Cerebral Circulation
- Measurement of Cerebral Blood Flow by Ultrasonic Doppler Technique : Hemodynamic Correlation of Internal Carotid Artery and Vertebral Artery
- Measurement of Cerebral Blood Flow by Ultrasonic Doppler Technique : Pulsatile Variation of Vascular Diameter of Human Common Carotid Artery
- Measurement of Cerebral Blood Flow by Ultrasonic Doppler Technique Hemodynamic Correlation Between Cerebral and Peripheral・ophthalmic Artery