EVALUATION OF TRANSIENT HEART MURMUR RESEMBLING PULMONARY ARTERY STENOSIS IN TERM INFANTS BY DOPPLER AND M-MODE ECHOCARDIOGRAPHY
スポンサーリンク
概要
- 論文の詳細を見る
Four term infants with transient murmurs resembling that of pulmonary artery stenosis were examined. A grade 3/6 systolic ejection murmur was transmitted clearly to the entire precordium and the back. This murmur was first detected 7 days after birth in 1 infant and at a 1-month medical check in the other 3. The murmur continued for 7 to 22 weeks, with an average of 12 weeks. It gradually localized in the region of the left sternal border, and eventually disappeared. At the first medical examination, peak velocities of over 2.0 m/s, in the left or right pulmonary artery, were detected by a pulsed Doppler. The diameter of the right pulmonary artery was small (mean, 58±8% ; range, 46 to 64% of predicted normal) . When the heart murmur disappeared, the diameter of the right pulmonary artery (mean, 97±28%; range, 70 to 126%) had increased significantly (p<0.05). Peak velocities in the right pulmonary arteries had decreased significantly (2.22±0.37 m/s vs 1.13±0.10 m/s, p<0.01). We suggest that hypoplasia of pulmonary artery branches, in relation to the main trunk, is the main cause of the murmur resembling pulmonary artery stenosis.
- 社団法人日本循環器学会の論文
- 1993-01-20
著者
-
Yokoyama Tatsuo
Division Of Pediatric Cardiology
-
MIYAKE TOSHIHARU
Division of Pediatric Cardiology, Department of Pediatrics, Kinki University School of Medicine
-
Yokoyama Tatsuo
Division Of Pediatric Cardiology Department Of Cardiovascular Surgery Kinki University School Of Med
-
Miyake Toshiharu
Division Of Pediatric Cardiology Department Of Cardiovascular Surgery Kinki University School Of Med
関連論文
- FACTORS AFFECTING BIVENTRICULAR FUNCTION FOLLOWING SURGICAL REPAIR OF TETRALOGY OF FALLOT
- ANGIOCARDIOGRAPHIC EVALUATION OF VENTRICULAR SEPTAL DEFECT : Pre- and Post-operative Cardiac Volume Characteristics
- Successful Planned Pregnancy in a Patient With St Jude Medical Prosthetic Mitral Valve
- -0075- EVALUATION OF PHYSICAL ACTIVITY IN CHILDREN USING ACCELERATION SENSOR.(PROCEEDINGS OF THE 59th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCULATION SOCIETY)
- Spontaneous closure of ventricular septal defects followed up from
- EVALUATION OF TRANSIENT HEART MURMUR RESEMBLING PULMONARY ARTERY STENOSIS IN TERM INFANTS BY DOPPLER AND M-MODE ECHOCARDIOGRAPHY
- Evaluation of pulmonary regurgitation by pulsed Doppler echocardiography and Doppler color flow imaging