1909 核熱結合試験用コンダクタンス型ボイド率計の開発
スポンサーリンク
概要
- 論文の詳細を見る
Conductance-type void fraction meter is a practical void fraction meter. It can apply to various test section (Round flow path, rectangular flow path, and rod bundle with squire lattice or triangular lattice). The principle of the meter is based on the fact that the electrical conductance changes with the change of void fraction in gas-liquid two-phase flow. According to air/water two-phase flow experiment, it was confirmed that void fraction α could be obtained by measuring I/Io (Io is current at α=0). The relation between α and I/Io agreed with Maxwell's equation. The void fraction meter can be applied to high temperature/high pressure condition (290℃, 7MPa), by taking account of temperature dependency of water specific conductance. It was succeeded to measure the void fraction of steam/water two-phase mixture in 2×2 bundle flow path in the range of 0%-60% under high temperature/high pressure condition.
- 一般社団法人日本機械学会の論文
- 2002-09-20
著者
関連論文
- 電気式ボイド率計による低減速炉稠密バンドル体系のボイド率測定(FR2 計測制御の最先端)
- 低減速炉稠密流路におけるスペーサ効果基礎実験 : 中性子ラジオグラフィ法によるフローパターンと沸騰熱伝達の同時測定(FR2 計測制御の最先端)
- 1910 THYNC 流量変動試験における沸騰遷移と発熱棒温度
- 1909 核熱結合試験用コンダクタンス型ボイド率計の開発