110 維持規格における評価不要内部欠陥寸法の導出法
スポンサーリンク
概要
- 論文の詳細を見る
In the Fitness for service (FFS) code, the evaluation procedure of the allowable depth for an embedded flaw from that of a surface flaw which has been decided from nondestructive testing is necessary. In this paper, the re-characterization procedure of an embedded flaw was derived by equating the stress intensity factor of an embedded flaw with that of a surface flaw. In addition, the condition that an embedded flaw is considered to be a surface flaw because of ligament plastic breakthrough was clarified. This proposed condition was compared with that of JSME and ASME code.
- 2002-08-23
著者
関連論文
- Cr-Mo鋼のクリープ脆化割れに及ぼす不純物含有量と溶接後熱処理条件の影響
- KHK基準解説 「超高圧ガス設備に関する基準」(KHK S 0220(2004))について(その2)材料に対する要求靱性値
- 110 維持規格における評価不要内部欠陥寸法の導出法
- 205 構造規格における安全率の維持規格に及ぼす影響
- 307 アルミニウム溶接部の疲労寿命評価
- 水素拡散挙動の差分法解析に基づく水素脆化評価