Control of Outflow Quantity from a Hopper : Application of STR Control
スポンサーリンク
概要
- 論文の詳細を見る
This paper presents an application of a self-tuning regulator to the control of a known amount of granules from a hopper. Generally, there are many kinds of stochastic disturbances in processes handling granules. For such processes, it is difficult to obtain a good performance by using conventional control methods. Therefore, we attempted to apply the self-tuning regulator to the process. In order to do this, it was necessary to have models of the process dynamics and of the disturbances. First, modeling of the disturbances is discussed, and the self-tuning algorithm is applied to our process. As for the results, it is shown that the self-tuning regulator is more robust and is very useful for processes handling granules.
- 一般社団法人日本機械学会の論文
- 1989-12-15
著者
-
Morioka H
Mitsubishi Electric Co. Ltd. Kobe Jpn
-
WADA Kenzou
Faculty of Engineering, Yamaguchi University
-
HAYANO Nobuo
Faculty of Engineering, Yamaguchi University
-
MORIOKA Hiroshi
Mitsubishi Electric Co., Ltd.,
-
Wada Kenzou
Faculty Of Engineering Yamaguchi University
-
Hayano Nobuo
Faculty Of Engineering Yamaguchi University
-
Morioka Hiroshi
Mitsubishi Electric Co.
関連論文
- Control of Outflow Quantity from a Hopper : Application of STR Control
- Control of outflow quantity from a hopper : application of adaptive control method
- Control of Outflow Quantity from Hopper : Application of LQ Control