309 温水曝気による VOC 含有水の処理システム
スポンサーリンク
概要
- 論文の詳細を見る
The remediation of VOC contaminated soil and underground water has been an social problem nationwide. We recently developed a new water treatment system for VOCs abatement by using a combination technology of aeration and combustion. In this system, VOC contaminated water is at first aerated to get VOCs out of water. The VOCs containing air is premixed with city gas and then burned. Combustion heat is used to warm the untreated water, so that the water is aerated around the temperature of 40℃. Comparing with the exiting treatment method of activated carbon adsorption, this system has higher VOCs removal rates without generating industry wastes. The burned gas was analyzed to check the concentration of dioxins and unburned VOCs.
- 一般社団法人日本機械学会の論文
- 2003-06-24
著者
関連論文
- 330 600〜900℃におけるメタン酸化に対する排ガス組成の影響(大気環境保全技術(II))(大気・水保全技術)
- 600〜900℃におけるメタン酸化に対する排ガス組成の影響
- オゾンによる未燃炭化水素の除去
- 13Aガス着火メカニズムの研究
- 304 燃焼排ガス中の水蒸気の凝縮液膜に対する NOx 吸収機構
- リバ-ニングにおけるNOx還元の研究(第3報:リバ-ニングゾ-ン拡散火炎における還元特性)
- 燃焼排ガスのドレンへのNOx吸収