304 燃焼排ガス中の水蒸気の凝縮液膜に対する NOx 吸収機構
スポンサーリンク
概要
- 論文の詳細を見る
Absorption rate of nitrogen dioxide (NO_2) at water surface was experimentally determined. Total concentration of nitrous (HNO_2) and nitric acid (HNO_3) was directly proportional to NO_2 concentration. It also depended on the water temperature and followed Arrhenius' law. The existence of NO did not have much influence on NO_2 absorption rate. Experiments of NO_x absorption at condensing heat exchanger were carried out. In this case, the concentration of NO^-_x(NO^-_2+NO^-_3) decreased as the condensation rate increased. It was shown that the amount of NO_x dissolved in condensate on heat exchanger increased as NO_2 concentration and condensation rate increased and was well correlated with the amount of NO_2 gas passing through heat exchanger.
- 一般社団法人日本機械学会の論文
- 2000-07-05
著者
関連論文
- 振動燃焼に関する研究(第2報:振動燃焼の数値解析)
- 330 600〜900℃におけるメタン酸化に対する排ガス組成の影響(大気環境保全技術(II))(大気・水保全技術)
- 600〜900℃におけるメタン酸化に対する排ガス組成の影響
- オゾンによる未燃炭化水素の除去
- 13Aガス着火メカニズムの研究
- 304 燃焼排ガス中の水蒸気の凝縮液膜に対する NOx 吸収機構
- リバ-ニングにおけるNOx還元の研究(第3報:リバ-ニングゾ-ン拡散火炎における還元特性)
- 燃焼排ガスのドレンへのNOx吸収
- 309 温水曝気による VOC 含有水の処理システム