両吸込うず巻ポンプの許容配管荷重に関する研究 : 第2報,ポンプケーシングに起因する軸端変位について
スポンサーリンク
概要
- 論文の詳細を見る
Shaft displacement due to pump casing deformation which occurs when external piping forces and moments are applied was investigated. The test pump was an axially split, single-stage double-suction volute type with foot support. An analysis by FEM (MSC/NASTRAN) and actual measurements were performed and considerable agreement was obtained. Ito was found that shaft displacement due to pump casing deformation can not be neglected in the case of pumps with foot support. In API 610-6th standard, limit of shaft displacement is 0.127 mm for pumps which have suction bores 300 mm or larger than 300 mm to enlarge this limitation. Effects of pump size and casing thickness on shaft displacement were investigated by FEM. The possibility of galling of casing wearing ring and considerable leakage from mechanical seal caused by piping loads also were investigated.
- 社団法人日本機械学会の論文
- 1985-05-25
著者
関連論文
- 両吸込みうず巻ポンプの許容配管荷重に関する研究 : 第1報,内圧を加味したケーシング応力分布について
- 立軸ポンプ用セラミックス軸受に関する研究 : 第2報,空気中および水中での摩擦係数について
- スラリ環境の軸受 (過酷条件におけるトライボロジ-)
- 立軸ポンプ用セラミックス軸受に関する研究 : 第1報,スラリー中における軸受の摩耗について
- 両吸込うず巻ポンプの許容配管荷重に関する研究 : 第3報,配管荷重によるポンプ脚部すべりについて
- 両吸込うず巻ポンプの許容配管荷重に関する研究 : 第2報,ポンプケーシングに起因する軸端変位について
- 高速高圧遠心ポンプの軸振動
- CN型ポンプを利用した動力回収用水車
- スパイラルグループ軸受の流れと最適寸法
- シュリンクフィッタを用いたレーザポリゴンミラーの高精度接合技術の開発
- セラミックスのポンプしゅう動部材への適用
- 水素化アモルファスカーボンの空気動圧軸受における潤滑薄膜としての検討
- 荏原設計情報管理システム《EDICS》 : 第10回ドクメンテーション・シンポジウム概要
- 多機能形超音波流量計の開発
- 新版API-610規格の概要と問題点-5-
- 新版API-610規格の概要と問題点-4-
- 新版API-610規格の概要と問題点-3-
- 新版API-610規格の概要と問題点-2-
- 新版API-610規格の概要と問題点-1-