夜間放射冷却利用の自然循環式蓄冷システムの研究
スポンサーリンク
概要
- 論文の詳細を見る
The performance of a sky radiative thermosyphon cooling system for storing thermal energy in a tank was studied experimentally and analytically. The system consisted of a storage tank of 66.7 litters and one or two black-painted plates (1.8 or 3.6m^2) facing the sky. They were connected by insulated tubes of 16 mm in inner diameter. The terperature at the outlet of the palte was 2〜6℃ below ambient temperature during clear nights. The water in the storage tank was cooled down to about ambient temperature. In the analysis, the temperature distributions in the storage tank were calculated numerically by considering the thermosyphon flow rate and the temperature changes of the fluid along the radiator and the connecting tubes. The analytical results were found to agree well with the experimental results.
- 一般社団法人日本機械学会の論文
- 1987-03-25
著者
関連論文
- 平板形太陽集熱器の集熱性能の改善 : 対流防止用フィルムの効果
- 潜熱蓄熱器の熱特性 : 第1報、カプセル形潜熱蓄熱器の蓄熱特性
- 潜熱蓄熱用円筒カプセルの伝熱問題 : 壁温が徐々に変化する場合の相変化
- 夜間放射冷却利用の自然循環式蓄冷システムの研究