Air-water Annular Two-phase Flow in a Horizontal Tube : 2nd Report, Circumferential Variations of Film Thickness Parameters
スポンサーリンク
概要
- 論文の詳細を見る
Experimental investigation was made on circumferential variations of the characteristics of a liquid film formed on the inner surface of a horizontal tube of 26.0 mm I.D. in which air and water flowed concurrently. Superficial velocities of the both phases ranged 10〜50 m/s for air and 0.006〜0.40 m/s for water. The flow pattern concerned was mainly an annular flow. Annular flow is subdivided into two regions characterized by liquid slug like frothy liquid lump (A_F-region) and disturbance wave (A_D-region). Classification can be made by examining the shape of the cumulative wave frequency distribution, plotted on normal probability paper against the radial distance from tube inner wall. A new method is proposed for separating base film from disturbance wave, which is processed on the wave frequency distribution chart. Experimental data are presented on principal parameters of liquid film such as thickness of base film, disturbance wave-height, -frequency and -velocity. A consideration is also made on the liquid transportation in disturbance wave region.
- 一般社団法人日本機械学会の論文
著者
-
FUKANO Tohru
Faculty of Engineering, Kyushu University
-
SEKOGUCHI Kotohiko
Faculty of Engineering, Kyushu University
-
Fukano Tohru
Faculty Of Eng. Kyushu Univ.
-
Morimoto Takao
Technical College Of The University Of Tokushima
-
OUSAKA Akiharu
Technical College of the University of Tokushima
-
Sekoguchi Kotohiko
Faculty Of Eng. Kyushu Univ.
関連論文
- Generation of a Disturbance Wave on a Liquid Film Flowing Down a Heated Inclined Plane
- Transient Behavior of a Gas Slug : 2nd Report, On the liquid film thickness around a gas slug
- Gas-liquid Two-phase Flow in Double-Tubes-Annular-Passage with Flow Obstruction : 1st Report, Effect of Flow Obstruction on Minimum Film Thickness)
- Film Thickness in Gas-Liquid Two-Phase Flow : 4fh Report, Film Thinning Mechanism During the Drainage
- Film Thickness in Gas-Liquid Two-Phase Flow : 3rd Report, Effects of Obstacle Length and Gap between Obstacle and Tube Surface
- Nondimensional Expression for the Relation between Pressure Drop and Flow Rate in Steam Generating Tubes
- Liquid Films Flowing Concurrently with Air in Horizontal Duct : 5th Report, Interfacial shear stress
- Liquid Films Flowing Concurrently with Air in Horizontal Duct : 4th Report, Effect of the geometry of duct cross-section on liquid film flow
- Liquid Films Flowing Concurrently with Air in Horizontal Duct : 3rd Report, The relation between occurrence of viscous wave and breakdown of liquid film
- Flow Simulation of Forced-Flow Boiling with Air-Water Two-Phase Fluids : 1st Report, On the Distribution of Bubbles
- A Technique for Measuring an Unsteady Temperature Distribution in a Liquid using Holographic Interferometry
- Heated Liquid Film Flow and Its Breakdown Caused by Marangoni Convection : The Characteristic Flow of Pure Water
- Liquid Films Flowing Concurrently with Air in Horizontal Duct : 2nd Report, Characteristics of Two-Dimensional Wave and Disturbance Wave Regions
- Liquid Films Flowing Concurrently with Air in Horizontal Duct : 1st Report, Flow Pattern
- Air-water Annular Two-phase Flow in a Horizontal Tube : 2nd Report, Circumferential Variations of Film Thickness Parameters
- Air-water Annular Two-phase Flow in a Horizontal Tube : 1st Report, Circumferential Distribution of Film Thicknesses
- On Ripple of Annular Two-Phase Flow : 3.Effect of Liquid Viscosity on Characteristics of Wave and Interfacial Friction Factor
- On Ripple of Annular Two-Phase Flow : 1. Statistical Characteristics of Ripples
- Investigation into the Statistical Characteristics of Bubbles in Two-Phase Flow : 2nd Report. Application and Establishment of Electric Resistivity Probe Method
- Investigation into the Statistical Characteristics of Bubbles in Two-Phase Flow : 1st Report. Fundamentals of the Instrumentation Using the Electric Resistivity Probe Technique
- Characteristics of Flow Fluctuation in Natural Circulation Air-Lift Pump : 1st Report, Relation between Characteristics of Flow Fluctuation and Flow Rate of Circulating Water
- Transient Behavior of a Gas Slug : 1st Report, On an ascending gas slug with rapid growth
- Two-Phase Flow Measurements with Orifice-Couple in Horizontal Pipe Line : 1st Report, Various Compositions of Orifices for Orifice-Couple and Appropriate Area Ratio of Opening
- Two-Phase Flow Characteristics in the Disturbed Flow Region after Mixing Air and Water
- An Investigation of the Flow Characteristics in the Disturbance Wave Region of Annular Flow : 1st Report, Effect of Tube Diameter
- Prediction Method of Flow Patterns in Subcooled and Low Quality Boiling Regions
- Prediction of Void Fraction in Subcooled and Low Quality Boiling Regions
- On the Determination Method of Entrained Droplet Flow Rate in the Disturbance Wave Region of Annular Flow
- Phase Distribution for Air-water Two-phase Flow in Annuli
- Analyses and Field Tests of Once-Through Boiler Dynamics
- On the Pulsation Phenomena in Gas-Liquid Two-Phase Flow : Relationship between Pulsating Pressure and Flow Pattern in Upward Two-Phase Flow
- Dynamics of Pressure in Forced-Flow Evaporator System
- Two-Phase Flow in Spirally Grooved Tubes
- On the Flashing Flow of Saturated Water Through Horizontal Pipes
- Study of Air-Water Two-Phase Centrifugal Pump by Means of Electric Resistivity Probe Technique for Void Fraction Measurement : 1st Report, Measurement of Void Fraction Distribution in a Radial Flow Impeller
- Void Signal Analysis and Gas-Liquid Two-Phase Flow Regime Determination by a Statistical Pattern Recognition Method : Fluids Engineering
- Discrete Frequency Noise Due to Irregularity in Blade Row of Axial Fan Rotor
- Statistical Evaluation of Liquid Phase Distributions in Gas-liquid Two-phase Flow : Froth and Huge Wave Flow Regim
- An Investigation into the Flow Characteristics in Froth Flow and the Transition Region between Froth and Annular Flow : 1st Report, On Liquid Lumps
- Liquid Films Flowing Concurrently with Air in Horizontal Duct : 6th Report, Generation of a Disturbance Wave and its Role in the Breakdown of Liquid films
- On the Gas-Liquid Two-Phase Flow inside Two Adjacent Subchannels with Different Cross-Sectional Areas