脳脊髄液短絡路内の流量評価法 : 流量と放射能クリアランスの関係
スポンサーリンク
概要
- 論文の詳細を見る
The estimation of flow rate in cerebrospinal fluid shunt was evaluated in vitro using radionuclide and a gamma camera. Approximately 50-100 μCi of ^<99m>Tc-pertechnetate in a volume of 0.05 ml was injected into a Pudenz 12 mm or a standard Rickham reservoir through a 26-gauge needle, and a time-activity curve at the region of the reservoir was recorded for a duration of 10 minutes with a gamma camera and data processor (Picker Dyna Camera 2C). The flow rate of the perfusion fluid in the shunt system was controlled by a hydrostatic pressure with a siphon or an infusion pump. The flow rates were changed from 0.01 ml/min to 1.0 ml/min. This range covered the rate of cerebrospinal fluid production. The perfusion fluid was distilled water or diluted alubumin solution. The time-activity curves represented the radioactivity clearance from the reservoir, and they showed two exponentials (the first and the second compartments) on the experiments using an infusion pump. The flow rates (F ml/min) determined from the radioactivity clearance half-time (T_<1/2> min) of the first compartment were identical with those calculated from the classical clearance formula, F=0.693 V/T_<1/2> where V is the physical volume (V ml) of the reservoir. On the other hand, the relationships between F and T_<1/2> of the second compartment were -1.3 log_<10>(T_<1/2>) - 0.016 ≦ log_<10>(F) ≦ -1.3 log_<10>(T_<1/2>) + 0.16 in the Pudenz reservoir and -1.9 log_<10>(T_<1/2>) - 0.12 ≦ log_<10>(F) ≦ -1.8 log_<10>(T_<1/2>) + (0.076 in the Rickham reservoir, which coincided with the results of the experiments using a siphon in each reservoir. The regression equation was log_<10>(F) = -1.3 log_<10>(T_<1/2>) + 0.087 or log_<10>(F) = -1.8 log_<10>(T_<1/2>) + 0.019 in the Pudenz reservoir or the Rickham one, respectively. The concentration of the albumin in the perfusion fluid, ranging between 25 mg/dl and 5,000 mg/dl, showed no significant effect o the T_<1/2> of the second compartment. In the Rickham reservoir, however, it was difficult to record the T_<1/2> of the second compartment when the albumin was more than 1,000 mg/dl, because the radioactivity in the reservoir was quickly cleared during the first compartment in these conditions. The duration of the first compartment observed on the experiment using an infusion pump was within only a few minutes at each flow rate, which is too short to record in clinical practice. Thus, the cerebrospinal fluid flow rate in the shunt system can be determined by using the above equations derived from the second compartment rather than the classical clearance formula.
- 日本脳神経外科学会の論文
- 1980-02-15
著者
-
森 厚文
金沢大学 学際センター
-
久田 欣一
金沢大学医学部
-
久田 欣一
金沢大学核医学教室
-
角家 暁
金沢医科大学病院統合医療情報システム開発プロジェクト
-
前田 敏男
金沢大学 核医
-
前田 敏男
金沢大学核医学科
-
角家 暁
金沢医科大学
-
森 厚文
金沢大学核医学科
関連論文
- 3)各種弁膜症における心筋スキャンの臨床的意義 : 日本循環器学会第45回北陸地方会
- 虚血性心疾患における安静時^I-BMIPP心筋シンチグラフィの意義 : ^Tl-運動負荷心筋シンチグラフィとの比較検討
- ぺースメーカー植え込み患者の運動負荷 : RI angiographyによる検討 : 日本循環器学会第40回北陸地方会
- 転移性骨腫瘍に伴う骨性落痛に対する放射性ストロンチウム(^Sr)製剤SMS.2Pの有用性 : 多施設における第111相臨床試験
- 転移性骨腫瘍に伴う骨性疼痛に対する放射性ストロンチウム(^Sr)製剤SMS.2Pの第II相臨床試験
- 運動負荷心筋シンチグラフィにおける^Tl分割投与法の検討 : 日本循環器学会第67回北陸地方会
- -1185-IMPROVEMENT OF EJECTION FRACTION RESPONSE PATTERN IN EXERCISE AFTER CORONARY ARTERY BYPASS GRAFTING (CABG) DETECTED BY AN AMBULATORY VENTRICULAR FUNCTION MONITOR (VEST) : THE 54th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCULATION SOCIETY
- -1170-^Tl STRESS MYOCARDIAL SCINTIGRAPHY IN VARIOUS HEART DISEASES WITH NORMAL CORONARY AMGIOGRAPHY : THE 54th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCULATION SOCIETY
- 41)位相解析による心室収縮様式の評価 : WPW症候群における副刺激伝導路の検出 : 日本循環器学会第48回北陸地方会
- 36)^Tl-心筋シンチによる肥大心の検討 : 日本循環器学会第48回北陸地方会
- 4)^Tl負荷心筋スキャンによる糖尿病性心筋障害の検討 : 日本循環器学会第45回北陸地方会
- 2)式室造影像と^Tl心筋スキャンの比較検討 : 日本循環器学会第45回北陸地方会
- 162)^Tl-負荷心筋シンチグラフィーによる肥大心の検討 : 日本循環器学会第65回東海・第50回北陸合同地方会
- Accuracy of cardiac PET imaging using post-injection transmission scan
- Myocardial viability assessment using nuclear imaging
- 56)プロタノール負荷心筋シンチによる虚血性心疾患診断の試み : 日本循環器学会第61回近畿地方会
- 核医学イメージングの規格化に関する勧告(1984年改訂)
- Single Photon Emission Computed Tomography装置の性能試験条件
- 91 下部胃癌におけるリンパ節転移の検討 : 特に3群リンパ節を中心として(第27回日本消化器外科学会総会)
- 403 ダブルアイソトープ法による胃リンパ流の検討(第26回日本消化器外科学会総会)
- 日本における放射性医薬品の揺籃期を振り返る
- 放射能の測定とモニタリング
- Triple Energy Window法による散乱補正が心筋SPECTの定量に及ぼす影響および2核種収集への応用
- 382. 3 検出器 SPECT 装置とその基本性能について(RI-10 装置・器具 1)
- 382. 3 検出器 SPECT 装置とその基本性能について(第 46 回総会学術大会会員研究発表予稿)
- 318 RI リンフオグラフイーを用いた S 状結腸リンパ流の検討(第28回日本消化器外科学会総会)
- 10. 原発性肺癌の^Ga single photon emission CTによる診断 : 第19回日本肺癌学会北陸支部会
- 4(Four)Energy Window(FEW)法による^Tcおよび^I2核種同時SPECT
- 焦点の異なった対向ファンビームコリメータ検出器によるSPECT : 第44回総会学術研究発表抄録 : RI-5 SPECT-1
- 185.焦点の異なった対向ファンビームコリメータ検出器によるSPECT : 第44回総会学術大会会員研究発表予稿
- FDG-PET imaging in duodenal cancer
- A case of renal pelvic tumor visualized by ^F-FDG-PET imaging
- OE-019 Is Post-stress Left Ventricular Dysfunction Related to The Severity of Coronary Artery Disease ? : A Gated Ammonia PET Study(Nuclear Cardiology 1 (I) : OE3)(Oral Presentation (English))
- Transient Dilation of the Left Ventricule Using ATP Stress N-13 NH_3 PET in Patients with Coronary Artery Disease
- Global and Regional Left Ventricular Function Assessed by ECG-Gated N-13 Ammonia PET in Patients with Coronary Artery Disease
- 陳旧性心筋梗塞例におけるTl再静注でFill-inを示す心筋での脂肪酸代謝に関する検討
- 心電図同期RI心プールに於けるフーリエ解析を用いたfunctional imaging : 日本循環器学会第43回北陸地方会
- Effect of left ventricular function on diagnostic accuracy of FDG SPECT
- Assessment of Global and Regional Left Ventricular Function by Electrocardiographic Gated N-13 Ammonia Positron Emission Tomography in Patients With Coronary Artery Disease
- -P121- LEFT VENTRICULAR FUNCTION IN ASYMPTOMATIC DIABETIC PATIENTS WITH PERFUSION DEFECTS IN TL-201 STRESS SCINTIGRAPHY
- 脳レセプタイメージング (その2) SPECT用製剤
- 脳レセプタイメージング (その1) PET用製剤
- ^Tc-HMPAO を用いる脳血流 SPECT の臨床的有用性
- E-25 てんかん患者における抗てんかん薬の副作用としてのrCBFの全般的低下 : ^I-IMP SPECTによる定量評価から
- II-C-29 I-^IMPとTc-99m-HM-PAOを用いたSPECTによるてんかん性幻聴について
- I-E-6 N-Isopropyl-p(^I)Iodoamphetamine(^I-IMP)静注法を用いたSPECTによる成人てんかん患者の局所脳血流測定 : 側頭葉てんかんにおける間欠期脳波焦点とSPECT焦点のlateralityの不一致について
- 同一患者における^Tc-MIBIと^T1の骨軟部腫瘍への集積の比較
- 1.Thallium-201 SPECT法による原発性肺癌の診断(第23回日本肺癌学会北陸支部会)
- 99mTc燐酸化合物による両側腎瀰慢性異常集積の臨床的考察
- EVALUATION OF MYOCARDIAL DAMAGE IN DIABETES MELLITUS USING EXERCISE THALLIUM SCINTIGRAPHY : Cardiomyopathy : II : 48 Annual Scientific Meeting, Japanese Circulation Society
- D-20 Thalliuml-201 SPECT法による小肺病巣の診断
- 安全管理 技術報告 放射性有機廃液中のRI除去
- ^3H-標識化合物の放射線分解による揮発性分解物の生成
- 有機廃液中の放射能除去
- ^3H および ^C-標識化合物の保存中の自己分解 - 開封時における気化しやすい放射性分解物による内部被曝 -
- 新しい液体シンチレ-ションカウンタ用固体シンチレ-タ"Ready Cap"の性能試験
- 脂環式合成アミノ酸--その構造と腫瘍親和性の相関性
- 14C標識脂環式アミノ酸類の合成--低放射能14C-KCNからの高収率・高比放射能合成と分析
- 14C-標識アミノ酸,糖類似物質および核酸前駆物質の腫瘍親和性
- 照射位置決め装置としてのシンチカメラの応用 : 特に肺癌照射野の判定とRI悪性腫瘍陽性描画法 : 北陸支部 : 第5回支部活動
- 脳脊髄液短絡路内の流量評価法 : 流量と放射能クリアランスの関係
- 硬膜下血腫ならびに硬膜下水腫における核医学的診断--脳シンチグラム・パタ-ン分類
- 放射性医薬品の品質管理
- 髄膜炎後26年目に脳スキャンにて発見された硬膜下水腫の1症例
- 頭部疾患における99mTc-EHDPの臨床的意義
- 脳シンチグラム-3-Crescentic patternならびにFrontal lucency sign(シンチグラム供覧)
- 脳シンチグラム-2-"doughnut"sign(シンチグラム供覧)
- 脳シンチグラム-5-Tail(Trailing edge)sign
- 脳梗塞の核医学的診断--脳シンチグラム・パタ-ン分類
- 頭蓋内疾患における核医学診断に関する研究--特に定量化による質的診断
- 38)WPW症候群における断層心プール像を用いた早期収縮部位の解析 : 日本循環器学会第51回北陸地方会
- 3検出器SPECT開発の意義 (放射線の応用--現状と今後の展望) -- (医療分野)
- III-B-18 小児のう胞性疾患における肺切除后肺機能について
- Technetium-99m tetrofosmin uptake in lung cancer: Comparison with thallium-201
- Intense accumulation of Tc-99m MDP and Ga-67 in multiple periapical cemental dysplasia
- APPLICATION OF PHASE ANALYSIS TO DETECT THE SITE OF ACCESSORY CONDUCTION PATHWAY USING GATED BLOOD POOL TOMOGRAPHY : Doppler, RI : I : 48 Annual Scientific Meeting, Japanese Circulation Society
- 腫瘍核医学の20世紀の歩みと21世紀の展望
- 46年を回顧して
- ラジオアイソトープの治療への応用 VII. 新しいRI内用療法 -放射免疫療法, 放射線滑膜切除術, 骨転移の除痛療法-
- 特別講演 : 泌尿器核医学の現状 : 第356回北陸地方会
- SPECT による心筋 viability の評価
- D-19 Tl-201 SPECT法による小肺腫瘤状病巣の診断
- P-69 T1-201 SPECTによる肺腫瘤状病巣の組織診断
- 肝臓の核医学(画像で見る代謝-7-)
- インビボ核医学の1980年代における役割
- 251 先天性胆道拡張症の画像診断による検討
- 胆道疾患における核医学診断 (胆道結石・ジスキネジ-)
- 60)糖尿病性心筋障害におけるTl-201Washout Rateの検討 : 日本循環器学会第54回北陸地方会
- 27.筋・軟部組織ラグビー外傷の超音波診断 : スポーツ医学に関する研究
- 23.ラグビー選手の血中ミオグロビンラジオイムノアッセイによるスポーツ医学への応用 : 運動生理学的研究I
- Thallium-201 Single Photon Emission Computed Tomography法による原発性肺癌の診断
- シンチカメラによる133Xe吸入法局所脳血流量測定用コリメ-タの試作
- In-111標識抗ヒトメラノーマモノクローナル抗体 (ZME-018) により脳転移が描出された悪性黒色腫
- 21) 糖尿病症例における^Tl心筋シンチ像 : 多施設における検討 : 日本循環器学会第46回北陸地方会
- RIシンチグラフィ-;心筋シンチグラフィ- (循環器疾患の画像診断)
- 膵シンチグラム (膵臓疾患)
- 核医学の現状と展望--耳鼻咽喉科領域を中心として
- 放射薬理・薬品学への積極的参加を
- RI診断法 (イメ-ジング綜合診断法特集--CT・超音波・RI) -- (イメ-ジング診断法の知識)
- ラット脳における3H-スピロペリド-ルによる受容体マクロオ-トラジオグラフィ