Kct lines of titanium through zinc have been observed from a high-temperatureplasma in a vacuum spark. The transition wavelengths of the He-like resonancelines are first determined under careful experimental procedures. The result iscompared with theoretical predictions and is in good agreement with that givenby Safronova. The theoretical values, however, include uncertainties in relati-vistic and QED corrections of the He-like resonance line. More accurate theore-tical values are required for comparison with these experimental data.