Spectral responsivity measurement of radiation detectors by using optical fiber beamsplitters
スポンサーリンク
概要
- 論文の詳細を見る
rights: 社団法人照明学会rights: 本文データは学協会の許諾に基づきCiNiiから複製したものであるrelation: IsVersionOf: http://ci.nii.ac.jp/naid/110001144373/The spectral responsivity measurement of radiation detectors by using optical fiber bundle beamsplitters is carried out. In this measurement, the optical fiber beamsplitter is set between a monochromator exit slit and two (standard and test) detectors. The bundle devides exit monochromatic radiation flux into two beams for standard and test detectors and also improves irradiance uniformity. The spectral responsivities of several Si photodiodes are measured by two different types of optical fiber bundle beamspliters and are compared with those by a conventional precise replacement method (replacement method). The results are as follows;(1) There is no essential difference between the results of our method and replacement one. (2) On our method, the standard and test detectores are measured at the same time (synchronous comparison method), so the intensity stability of a radiation source becomes less important. (3) The measurement period by use of the optical fiber beamsplitter becomes less half of that of replacement method. (4) The results of measurements are not influenced by the types of fiber bundles which have considerably different material, dimension and the number of single element fiber in our case.
- 社団法人照明学会の論文
著者
-
Jie Tang
Department Of Astronomy Beijing Normal University
-
Ke-ping Zhou
Department Of Astronomy Beijing Normal University
-
Nakagawa Y
Saitama University
-
Nakagawa Yasuo
Department Of Applied Physics Faculty Of Engineering Osaka University
-
Yun-xiang Hao
Department Of Astronomy Beijing Normal University
-
OHTANI FUMIO
Department of Physiology, Shimane Medical University
-
YAJI Tamaki
Department of Electronic Engineering, Faculty of Engineering Saitama University
-
Yaji T
Saitama University
-
Yaji Tamaki
Department Of Electrical Engineering Faculty Of Science And Technology Keio University
-
OHTANI Fumio
Saitama University
-
Ohtani Fumio
Department Of Physiology Shimane Medical University
-
中川 靖夫
Department of Astronomy, Beijing Normal University
関連論文
- Characteristics of High-Sensitivity Ge Bolometer
- Low Temperature Properties of the Reststrahlen Powder Filters in the Far-Infared Region
- Levels of ATP in Different Areas of Contracting Rabbit Aorta under Aerobic Conditions
- Activity of Phosphofructokinase during Lactate Accumulation in Rabbit Aorta
- Spectral responsivity measurement of radiation detectors by using optical fiber beamsplitters
- Domestic Comparison of Relative Spectral Responsivity Measurements for Illuminance Meters
- Study on Cavity Type Thermal Radiation Detector (1) : Consideration on Effective Absorption of Conical Cavity Detector (The Abstracts of the Papers Published in J.Illum. Engng. Inst. Jpn. Vol. 82, 1998 No. 2)
- Development of a Photometer Having Variable Spectral Responsivity
- Development of an Infrared Irradiance Meter
- Submillimeter Absorption in p-Type Germanium
- Influence of Ag Photodoping on Photoinduced Changes in As_2S_3 Glass Films
- Absorption Efficiency and Biological Half-Life of Individual Chlorobiphenyls in Rats Treated with Kanechlor Products
- Studies on Hydroxy Amino Acids. IV. Syntheses of Several Peptides Containing Aziridinecarboxylic Acid Derived from the Corresponding Hydroxy Amino Acid Derivatives