SEPAC (Space Experiment with Particle Accelerators) accelerators were tested in NASDA Large Space Chamber. The accelerators were Engineering Models of EBA (Electron Beam Accelerator) and MPD (Magnetoplasmadynamic arcjet). EMI (Electromagnetic Interference) data were obtained for EBA and MPD arcjet and no interference both electronic and via plasma was observed between these accelerators. Charge neutralization was successfully attained when MPD arcjet or NGP (Neutral Gas Plume) and EBA were simultaneously operated. Beam and plasma injections were clearly observed by a monitor TV camera.
- 宇宙航空研究開発機構の論文
著者
-
Kudo Isao
Electrotechnical Laboratory
-
Sasaki Susumu
Institute Of Space And Astronautical Science
-
Kawashima N
Inst. Space And Astronautical Science Kanagawa Jpn
関連論文
- Study of Spacecraft Environment on SFU
- Control of Levitation in Electromagnetic Levitators under Microgravity
- Synergistic Enhancement of Direct Synchrotron Radiation Etching of a Resist by a Low-Energy Oxygen Beam
- SEPAC System Test in NASDA Space Chamber
- SEPAC System Test in NASDA Space Chamber
- Diagnostic Studies of SEPAC Test in NASDA Space Chamber
- SEPAC Particle Accelerator Test in NASDA Space Chamber
- Vacuum-environment around Spacelab-1