Evaluation of the Applicability of Infrared and Thermistor-Thermometry in Thermophysiology Research
スポンサーリンク
概要
- 論文の詳細を見る
The accuracy and reliability of temperature measuring devices in thermal physiology research and clinical practice has been subject of various investigations. Research data have been conflicting in some cases. Further investigations are therefore needed to elucidate the reliability and sensitivity of these devices under different temperature settings. The aim of this study was to evaluate the reliability and sensitivity of the tympanic thermistor (TT), infrared tympanic thermometer (ITT) and oral thermistor (OT) in the detection of body temperature changes in adults exposed to heat load. A single set of three simultaneous temperatures i.e. oral, left and right tympanic membrane were measured. At rest, core temperature (Tc) measured by TT was 0.45℃ and+0.10~-0.12℃ (changed range) higher than that measured with OT and ITT respectively. At the end of 30min 43℃ water bath leg immersion, Tc measured by TT was 0.48℃ and 0.04℃ higher than that measured with OT and ITT. This showed that when subjects were exposed to heat load, there was no difference in Tc measured by TT and ITT, although both were significantly higher than that measured with OT. From these results, it might be thought that the sensitivity for Tc detection increased in the order tympanic thermistor>infrared thermometer>oral thermistor. Further-more, in addition to the merits of infrared thermometer, the hazards and difficulties of tympanic temperature measurement were discussed from the view of development of the various kinds of thermometers.
- 長崎大学の論文
著者
-
Timothy Othman
Healthcare Equipment Development Center Omron Institute Of Life Science
-
Kosaka Mitsuo
Department Of Physiology Nagoya City University Medical School
-
LEE JEONG-BEOM
Department of Immunology, Medical College of BK21 Biomedical Sciences, Korea University
-
Jeong-Beom Lee
Technology and Science Department, Healthcare Company, OMRON Corporation
-
Jeong-beom Lee
Technology And Science Department Healthcare Company Omron Corporation
-
Kosaka Mitsuo
Department Of Environmental Physiology Institute Of Tropical Medicine Nagasaki University
-
Kosaka Mitsuo
Department Of Environmental Physiology Institute Of Tropical Medicine
-
Kosaka Mitsuo
Technology and Science Department, Healthcare Company, OMRON Corporation
-
Othman Timothy
Healthcare Equipment Development Center, OMRON Institute of Life Science
-
Lee Jeong-Beom
Department of Environmental Physiology, Institute of Tropical Medicine, Nagasaki University, Nagasaki 852-8523, Japan
関連論文
- 熱帯地域のマレーシア住民が温帯地域の日本滞在による順化に伴なう発汗運動変異
- Heat-Shock Proteins Induced by Transient Brain Ischemia
- Evaluation of the Applicability of Infrared and Thermistor-Thermometry in Thermophysiology Research
- In Vivo NMR Micro-Imaging of Kidney and Liver of Mouse at 9.4 T
- RESPIRATORY RESPONSE TO THERMAL STIMULATION OF SPINAL CORD IN CONSCIOUS DECEREBRATED RABBIT
- Effects of Fluid Ingestion During Intermittent High Intensity Swimming Exercise on Thermoregulatory Responses and Performance
- S07-2 Modification of Human Sweating by Heat Acclimatization : Short-Term versus Long-Term Acclimatization(Proceedings of The 8th International Congress of Physiological Anthropology)
- A Field Study of Telemetry-Recording of The Body Temperature in Wild Mongolian Pikas
- Effect of Cardiac Rehabilitation and Statin Treatment on Anti-HSP Antibody Titers in Patients With Coronary Artery Disease After Percutaneous Coronary Intervention
- REFLEX INHIBITION OF COLD SHIVERING DUE TO ELECTRICAL STIMULATION OF THE CUTANEOUS NERVE FIBER
- INHIBITORY EFFECT OF ELECTRICAL STIMULATION OF THE SPINAL CORD ON COLD SHIVERING
- Study on Skin and Eccrine Sweat Glands
- Thermobiological Characteristics of Pikas, Rabbits and Rats
- Heat-Shock Proteins Induced in Mammals by Whole Body Hyperthermia
- EFFECT OF THERMAL STIMULATION OF SPINAL CORD ON OXYGEN CONSUMPTION IN THE RABBIT
- P2-4 Modification of central sudomotor mechanism and sweat responses on trained men
- P2-3 The effect of caffeine on the metabolic responses lipolysis and activated sweat gland density in human during active heat loading