Pump Assisted Heat Pipe
スポンサーリンク
概要
- 論文の詳細を見る
A labortory model of a pump assisted heat pipe has been fablicated and tested. An arterial heat pipe with axial grooves and a gear pump with a magnetic coupling have been developed for the model. The test has been carried out successfully. The reasonable thermal conductance has been obtained so far as the necessary working fluid flow rate is supplied. The necessary flow rate exceeds the theoretical one and the excess flow rate increases as the heat load increases.
著者
-
MIYAZAKI Yoshiro
Toshiba Corp., Research and Development Center.
-
OSHIMA Shigeto
Toshiba Corp.
-
Miyazaki Yoshiro
Toshiba Corp.
関連論文
- Pump Assisted Heat Pipe
- Development of Titanium Heat Pipes for Use in Space
- Heat Transfer Characteristics of Arterial Heat Pipe with Axial Grooves
- Forced-Convective Boiling in Small Diameter Tube
- High Capacity Heat Pipe with Axial Grooves