Influence of Corona Discharge from a Wire Particle Located in a DC Electric Field on its Precessional Motion
スポンサーリンク
概要
- 論文の詳細を見る
Influence of corona discharge on the precessional motion of a wire particle located in a dc electric field formed by a parallel plate electrodes system was investigated experimentally. A copper wire with 0.25 mm in diameter and 6 mm in length was used as a wire particle. When an applied voltage to the parallel plate electrodes exceeded the lift-up voltage for the wire particle placed at the lower electrode, the particle moved in several manners depending on the polarity of applied voltage or polarity of the particle. A negative particle kept standing or precessional motion stably while a positive particle tended to cause spark or to leave the lower electrode and cross the gap. During precessional motion of a negative particle, a micro gap often formed between the wire particle and the lower electrode. From the analysis of high speed pictures of precessional motions, it was shown that the rotation speed of the particle was strongly affected by the edge shape of the wire particle. Corona discharge is a source of rotational and precessional motion. Space charge formed at a vicinity of the wire particle would inevitably play an important role to make a particle rotate and tilt associating with induced charge at the tip of the particle.
- 社団法人 電気学会の論文
- 2007-11-01
著者
-
Asano Kazutoshi
Department Of Electrical And Information Engineering Faculty Of Engineering Yamagata University
-
Asano Kazutoshi
Department Of Electrical Engineering Yamagata University
-
Kudo Yusuke
Department Of Electrical Engineering Yamagata University
-
HIGASHIYAMA Yoshio
Department of Electrical Engineering, Yamagata University
-
Higashiyama Yoshio
Department Of Electrical And Information Engineering Faculty Of Engineering Yamagata University
-
Higashiyama Yoshio
Department Of Electrical Engineering Yamagata University
関連論文
- Brush-like Discharge Extending from a Grounded Electrode toward a Large-scale Charged Particle Cloud
- Pleural space sterilization using gentian violet irrigation for postbullectomy empyema associated with artificial material infection
- Dependence of Plasma Density on Air Gap Length of Resonant Cavity with Bottom Plate Replaced by High-Density Plasma
- Influence of Corona Discharge from a Wire Particle Located in a DC Electric Field on its Precessional Motion
- Fundamental Characteristics of Hydrophilic Polymer (Polyether Block Amide) as a Humidity Sensor