Flame Spread and Damaged Properties of RCD Cases by Tracking (特集:平成18年〔電気学会〕電力・エネルギー部門大会)
スポンサーリンク
概要
- 論文の詳細を見る
In this paper, the flame spread and damaged properties of residual current protective devices (RCDs) by tracking were analyzed. Pictures of tracking process were taken by High Speed Imaging System (HSIS), and fire progression was observed by timeframe. During the tracking process of RCD, it seemed to explode just once in appearance, but in the results of HSIS analysis, a small fire broke out and disappeared repeatedly 35 times and a flash of light repeated 15 times. Finally, an explosion with a flash of light occurred and lots of particles were scattered. Electric muffle furnace was used for heat treatment of RCD cases. The surface characteristics of specimens due to heat treatment and tracking deterioration were taken by Scanning Electron Microscope (SEM). Chemical and thermal properties of these deteriorated specimens were analyzed by Fourier Transform Infrared Spectrometer (FT-IR) and Differential Thermal Analyzer (DTA). The carbonization characteristics showed different chemical properties due to energy sources, and the results could be applicable to judge the accident causes.
- 社団法人 電気学会の論文
- 2007-01-01
著者
-
Kim Hyang-kon
Electrical Safety Research Institute A Subsidiary Of Korea Electrical Safety Corporation
-
CHOI Chung-Seog
Electrical Safety Research Institute, a subsidiary of Korea Electrical Safety Corporation
-
KIM Dong-Woo
Electrical Safety Research Institute, a subsidiary of Korea Electrical Safety Corporation
-
SHONG Kil-Mok
Electrical Safety Research Institute, a subsidiary of Korea Electrical Safety Corporation
-
Kim Dong-ook
Electrical Safety Research Institute A Subsidiary Of Korea Electrical Safety Corporation
-
Shong Kil-mok
Electrical Safety Research Institute A Subsidiary Of Korea Electrical Safety Corporation
-
Choi Chung-seog
Electrical Safety Research Institute A Subsidiary Of Korea Electrical Safety Corporation
-
Kim Dong-woo
Electrical Safety Research Institute A Subsidiary Of Korea Electrical Safety Corporation
-
Choi Chung-seog
Electrical Safety Research Institute Subsidiary Of Korea Electrical Safety Corporation
関連論文
- Temperature diffusion distribution of electric wire deteriorated by overcurrent (特集:平成19年[電気学会]電力・エネルギー部門大会)
- Flame Spread and Damaged Properties of RCD Cases by Tracking (特集:平成18年〔電気学会〕電力・エネルギー部門大会)
- The Potential Gradient of Ground Surface according to Shapes of Mesh Grid Grounding Electrode using Reduced Scale Model (特集:平成17年〔電気学会〕電力・エネルギー部門大会)
- Analysis of Dispersive Characteristics and Structures of Copper Wire Melted by Overcurrent (特集:平成17年〔電気学会〕電力・エネルギー部門大会)