フェライトの動的磁気損失パラメータの一測定法
スポンサーリンク
概要
- 論文の詳細を見る
The measurement of the iron loss in ferrites is an important work for developing high efficiency switching power supplies. The authors have proposed the dynamic magnetic loss parameter, λf, for evaluating the iron loss in ferrites. In the previous studies, the parameter was assumed to be a constant value for an individual ferrite material and defined for one period of a small B-H loop. In this paper, assuming that λf is a function of the time derivative of the magnetic flux density, dB/dt, a novel measurement method of λf of a Ni-Zn ferrite is proposed using rectangular wave voltage excitation and the Fourier expansion of the exciting current. In order to realize an iron loss measurement system with the rectangular wave voltage excitation, a high frequency FET inverter has been developed. The results of measuring λf show that it is uniquely determined by dB/dt regardless of B-H loop size. The measured dB/dt characteristics of λf are applied to practical examples for switching power supplies and sinusoidal wave voltage excitations. Their experimental and computational results coincide and it is clarified that the measured dB/dt characteristics are effective and useful.
- 社団法人 電気学会の論文
- 2004-03-01
著者
関連論文
- ハイブリッド型DC-DCコンバータにおける出力平滑コンデンサリプル電流を大幅低減させるトランス設計法
- ハイブリット型DC-DCコンバータの出力電流リプル低減に関する検討
- ハイブリット型DC/DCコンバータに適用する四脚トランスの設計法
- 直流平滑機能を有する四脚トランスの一設計法
- ハイブリット型DC/DCコンバータに適用する四脚コアトランスの設計法
- 直流平滑リアクトル機能付DC-DCコンバータ用トランスの脚磁束解析(パワーマグネティックス)
- アクティブクランプ付フォワードコンバータの回路シミュレーション
- 多出力DC/DCコンバータにおけるクロスレギュレーションの解析(制御技術関連)
- 多出力DC/DCコンバータにおけるクロスレギュレーションの解析
- パワーマグネティックス : 解析技術II(磁気回路法による解析)