Calculation of Gamma-ray Exposure Buildup Factors up to 40mfp using the EGS4 Monte Carlo Code with a particle Splitting
スポンサーリンク
概要
- 論文の詳細を見る
Gamma-ray exposure buildup factors up to 40mfp have been calculated using the Monte Carlo code EGS4 for water, iron and lead for point isotropic sources. The new algorithm which applies particle-splitting at each preset depth to simulate almost same number of particles from the preset depth is developed in order to obtain reasonable results with EGS4 at deep-penetrations. Comparisons of these results to the standard data calculated with the moments method or the discrete ordinates code PALLAS show good agreements if the same cross section data and energy absorption coefficients are used.<BR>The EGS4 calculations with this new algorithm will be a useful tool for future studies of gamma-ray buildup factors including the review of the standard data.
- 社団法人 日本原子力学会の論文
- 1995-12-25
著者
-
Hirayama H
High Energy Accelerator Research Organization
-
HIRAYAMA Hideo
National Laboratory for High Energy Physics
関連論文
- Calculation of Gamma-Ray Buildup Factors up to Depths of 100 mfp by the Method of Invariant Embedding, (II) : Improved Treatment of Bremsstrahlung
- Comparison of Line Beam Response Function for Gamma-ray Skyshine Analysis Based on Single Scattering Method with the Monte Carlo Calculations
- Calculation of Gamma-ray Exposure Buildup Factors up to 40mfp using the EGS4 Monte Carlo Code with a particle Splitting
- Validity of the Four-Parameter Empirical Formula in Approximating the Response Functions for Gamma-ray, Neutron, and Secondary Gamma-ray Skyshine Analyses
- Calibration of Silicon PIN Photodiode for Measuring Intensity of 7-40 keV Photons.