概要
- 論文の詳細を見る
Miniaturized thermoacoustic systems are examined in this study for application to electronic equipment. Our previous studies revealed that stable oscillation can be achieved in miniature step-shape thermoacoustic closed-tube systems. However, closed-tube systems present problems: the temperature ratio of the stack cannot be formed to raise the temperature in the system. Moreover, the stack is thin. Miniature thermoacoustic systems have high loss because of the high frequency necessary to shorten the total length. Despite these problems, miniature step-shape thermoacoustic systems can achieve oscillation conditions. This paper concerns a step-shape thermoacoustic system, focusing on the temperature ratio and the quality value as parameters to estimate the loss in a system. Consequently, results show that the efficiency of the thermoacoustic system is improved by adopting a step-shape in the system, with the step-shape system being driven at low temperature.
- 2013-07-25
著者
-
Nakano Yosuke
Graduate School Of Science And Engineering Tokyo Institute Of Technology
-
Sakamoto Shin-ichi
Department of Electronic Systems Engineering, University of Shiga Prefecture, Hikone, Shiga 522-8533, Japan
-
Shibata Kenji
Graduate School of Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321, Japan
-
Watanabe Yoshiaki
Graduate School of Life and Medical Sciences, Doshisha University, Kyotanabe, Kyoto 610-0321, Japan
関連論文
- AFM Interaction Study of Poly(ammonium acrylate) Adsorbed on a Si Surface in Aqueous KCl Solution
- Applying Sub-Loop Tube to Control the Sound Field in a Loop-Tube-Type Thermoacoustic System
- Relation between Acoustic Impedance and Sound Intensity Amplification in a Stack of Standing-Wave Thermoacoustic Prime Mover (Special Issue : Ultrasonic Electronics)
- Fundamental Study for the Solution of Thermoacoustic Phenomenon Using Numerical Calculation : Relationship between the Stack Installation Position and Heat Flow (Special Issue : Ultrasonic Electronics)
- Energy Conversion from Sound to Heat Using Lamination Mesh on the Thermoacoustic System
- Applying Diverging Tube for the Low-Temperature Drive in a Loop-Tube-Type Thermoacoustic System
- Heat Pump Placed in the Resonance Tube Connected to the Loop-Tube-Type Thermoacoustic Cooling System Improves the Cooling Effect
- Relationship between Quality Value and Temperature Ratio for Step-Shape Thermoacoustic System