Quantitative Evaluation of Liver Fibrosis Using Multi-Rayleigh Model with Hypoechoic Component
スポンサーリンク
概要
- 論文の詳細を見る
To realize a quantitative diagnosis method of liver fibrosis, we have been developing a modeling method for the probability density function of the echo amplitude. In our previous model, the approximation accuracy is insufficient in regions with hypoechoic tissue such as a nodule or a blood vessel. In this study, we examined a multi-Rayleigh model with three Rayleigh distributions, corresponding to the distribution of the echo amplitude from hypoechoic, normal, and fibrous tissue. We showed quantitatively that the proposed model can model the amplitude distribution of liver fibrosis echo data with hypoechoic tissue adequately using Kullback--Leibler (KL) divergence, which is an index of the difference between two probability distributions. We also found that fibrous indices can be estimated stably using the proposed model even if hypoechoic tissue is included in the region of interest. We conclude that the multi-Rayleigh model with three components can be used to evaluate the progress of liver fibrosis quantitatively.
- 2013-07-25
著者
-
Yamaguchi Tadashi
Research Center For Frontier Medical Engineering Chiba University
-
Hachiya Hiroyuki
Graduate School Of Science And Engineering Tokyo Institute Of Technology
-
Hachiya Hiroyuki
Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8552, Japan
-
Higuchi Tatsuya
Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8552, Japan
-
Hirata Shinnosuke
Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8552, Japan
関連論文
- Stability of Quantitative Evaluation Method of Liver Fibrosis Using Amplitude Distribution Model of Fibrotic Liver
- Quantitative Estimation Method for Liver Fibrosis Based on Combination of Rayleigh Distributions
- Position detection of small objects in indoor environments using coded acoustic signal
- Contour extraction of the right atrium for the thrombi measurement in TEE movies
- P3-7 Precise position measurement of objects using an acoustic M-sequence signal in the air(Poster session 3)
- P2-42 Measurement of the amount of embolic using Transesophageal echocardiography(Short oral presentation for posters)
- Proposal of a parametric imaging method for quantitative diagnosis of liver fibrosis
- Experimental Evaluation of Quantitative Diagnosis Technique for Hepatic Fibrosis Using Ultrasonic Phantom (Special Issue : Ultrasonic Electronics)
- The design of the ultrasonic three-dimensional filter for the liver disease diagnosis(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Transmission electron microscopy study on the effects of the ultrasound contrast agent Levovist on hepatic cells
- Verification of Ultrasonic Image Fusion Technique for Laparoscopic Surgery
- Target Detectability Using Coded Acoustic Signal in Indoor Environments
- Quantitative Evaluation of Liver Fibrosis Using Multi-Rayleigh Model with Hypoechoic Component
- Application of Ultrasonic Microscopy to Evaluation of Electrically Ligated Vessel Tissue
- Estimation of stability of acoustic reciprocal transmission in deep and coastal waters
- Application of Ultrasonic Microscopy to Evaluation of Electrically Ligated Vessel Tissue