Angular Distribution of Neutron Flux around the Tritium Target of 14 MeV Neutron Generator
スポンサーリンク
概要
- 論文の詳細を見る
The angular distribution of the 14 MeV neutrons emitted through D--T reaction was measured around the tritium target of a 14 MeV neutron generator using two different sample holders and also theoretically estimated. The samples were made out of 99.99% pure Aluminium foil and irradiated with the neutrons. In the neutron irradiated aluminum samples, the gamma-ray activity, induced through the nuclear reaction Al27(n,\alpha)Na24 was measured by a NaI(Tl) detector. Using one of the sample holders the axial distribution of neutron flux was also estimated. The discrepancy from the isotropic pattern was accounted for by reasons related to the in-between matrices and design of the tritium target mounting assembly.
- 2012-10-15
著者
-
Mandal Ranjita
Department of Geology and Geophysics, Indian Institute of Technology, Kharagpur 721302, India
-
Sengupta Debashish
Department of Geology and Geophysics, Indian Institute of Technology, Kharagpur 721302, India
-
BHORASKAR Vasant
Department of Nuclear Engineering, Nagoya University
-
Pansare Genu
Department of Physics, University of Pune, Pune 411007, India
-
Bhoraskar Vasant
Department of Physics, University of Pune, Pune 411007, India
関連論文
- Angular Distribution of Neutron Flux around the Tritium Target of 14 MeV Neutron Generator
- Cross section measurements of (n,n') and (n,2n) reactions on zirconium and lead targets at 14.8 MeV.
- Formation cross sections of zirconium-90m and lead-207m with fast neutrons.