Harmonic Imaging of Plastic Deformation in Thin Metal Plates Using Nonlinear Ultrasonic Method
スポンサーリンク
概要
- 論文の詳細を見る
Plastic deformation in perforated SUS 304 steel strips is imaged by an immersion resonant higher harmonic technique. The higher harmonic components are extracted from resonant waveforms received through a high-pass filter. Plastic zones are imaged by higher harmonic amplitude and delay time from the start of resonance to the peak amplitude. The higher harmonic amplitude corresponds well to the extent of plastic deformation; namely, it is highest in highly deformed regions and lowest in un-deformed regions. This technique could be applied to evaluate material degradation before crack initiation.
- 2011-07-25
著者
-
Kawashima Koichiro
Ultrasonic Materials Diagnosis Lab.
-
Kawashima Koichiro
Ultrasonic Materials Diagnosis Laboratory Ltd., Nagoya 466-0062, Japan
関連論文
- P3-24 Nonlinear acoustic evaluation of creep damage in boiler heat exchange tubes(Poster session 3)
- Backscattered Transverse Wave Imaging of Cracked-Faces with Linear and Nonlinear Ultrasonics
- Harmonic Imaging of Plastic Deformation in Thin Metal Plates Using Nonlinear Ultrasonic Method
- Nonlinear Acoustic Evaluation of Creep Damage in Boiler Heat Exchange Tubes