Comparison of Effective Working Electrode Areas on Planar and Porous Silicon Substrates for Cholesterol Biosensor
スポンサーリンク
概要
- 論文の詳細を見る
Porous silicon-based biosensors were originally developed to further stet the miniaturization of a host of devices. In this paper, we describe the relationship between the enlargement of an electrode’s area and its sensitivity for the determination of cholesterol concentrations with covalent binding to immobilized enzymes. For comparison, we conducted a series of experiments using a planar silicon electrode and a porous silicon electrode. We determined the effective surface area of the electrodes using the Randles–Sevcik equation. The active surface area of the planar electrode was approximately 0.1608 cm2, and that of the porous electrode was approximately 0.5054 cm2. Cholesterol oxidase was covalently immobilized on each electrode by silanization. The sensitivities were 0.08567 μA/mM for the planar sensor and 0.2656 μA/mM for the porous sensor. The calculated effective surface area and sensitivity of the porous electrode were about 3.1-fold larger than those of the planar electrode.
- 2006-09-15
著者
-
Song Min-jung
Department Of Chemical And Biological Engineering Korea University
-
Min Nam-ki
Depertment Of Control And Instrumentation Engineering Korea University
-
JIN Joon-Hyung
Department of Chemistry, Victoria University
-
Yun Dong-hwa
Department Of Chemical And Biological Engineering Korea University
-
Hong Suk-in
Department Of Chemical And Biological Engineering Korea University
-
Min Nam-Ki
Depertment of Control and Instrumentation Engineering, Korea University, 208 Seochang, Jochiwon, Yeongi, Choongnam 339-700, Korea
-
Jin Joon-Hyung
Department of Chemistry, Victoria University, Victoria, BC, Canada V8W 3V6
-
Song Min-Jung
Department of Chemical and Biological Engineering, Korea University, 1, 5-Ga Anam-dong, Sungbuk-ku, Seoul 136-701, Korea
-
Jin Joon-Hyung
Department of Biomicrosystem Technology, Korea University, Seoul 136-701, Republic of Korea
関連論文
- Electrochemical Biosensor Array for Liver Diagnosis Using Silanization Technique on Nanoporous Silicon Electrode(MEDICAL BIOTECHNOLOGY)
- Comparison of Effective Working Electrode Areas on Planar and Porous Silicon Substrates for Cholesterol Biosensor
- Purification and Characterization of Prodigiosin Produced by Integrated Bioreactor from Serratia sp. KH-95(BIOCHEMICAL ENGINEERING)
- An Electrochemical Biosensor Array for Rapid Detection of Alanine Aminotransferase and Aspartate Aminotransferase
- Fabrication and Electrochemical Characterization of Nanoporous Silicon Electrode for Amperometric Urea Biosensor (Special Issue : Microprocesses and Nanotechnology)
- Comparison of Effective Working Electrode Areas on Planar and Porous Silicon Substrates for Cholesterol Biosensor
- Dopamine Sensor Based on a Boron-Doped Diamond Electrode Modified with a Polyaniline/Au Nanocomposites in the Presence of Ascorbic Acid
- Biointerfacial Property of Plasma-Treated Single-Walled Carbon Nanotube Film Electrodes for Electrochemical Biosensors
- Plasma-Enhanced Surface Modification of Sprayed Carbon Nanotube Electrodes for Lithographically Integrated Biosensing System
- Estimation of carrier frequencies of six autosomal-recessive Mendelian disorders in the Korean population