Accuracy Depending on Scanning Angle in Dynamic Spot Size Measurement Method for an Optical Disk Drive
スポンサーリンク
概要
- 論文の詳細を見る
The spot size has been measured by chopping the beam spot with a knife edge on an optical disk. Tangential and radial spot sizes are measured with different two angled knife edges: θ1-edge and θ2-edge. In this paper, the errors in the measurement of spot sizes caused by the error in the scanning angle and the scanning velocity are described. The result of the theoretical analysis gives the best combinations of the scanning angles which are θ1=0°, θ2=±45° with the radial direction. For example, if the angle error of θ1 and θ2 obtained experimentally 0.64°, then the calculated error of the radial spot size is 2.2%. The analyzed error shows a good agreement with the experimental results. It was analytically observed that the influence of the scanning velocity error on the error of the measured spot sizes can be practically ignored using this method.
- Publication Office, Japanese Journal of Applied Physics, Faculty of Science, University of Tokyoの論文
- 1998-04-30
著者
-
Ogawa Akihito
Department Of Mechanical Engineering Faculty Of Engineering Shizuoka University
-
Kubo Takahiro
Department Of Applied Physics Faculty Of Engineering Tohoku University
-
Sugiura Akinobu
Department Of Mechanical Engineering Faculty Of Engineering Shizuoka University
-
KANEKO Toru
Department of Gastroenterology, Internal Medicine, Kitasato University East Hospital
-
Kaneko Toru
Department of Mechanical Engineering, Faculty of Engineering, Shizuoka University,
-
Kubo Takahiro
Department of Mechanical Engineering, Faculty of Engineering, Shizuoka University,
-
Ogawa Akihito
Department of Mechanical Engineering, Faculty of Engineering, Shizuoka University,
-
Sugiura Akinobu
Department of Mechanical Engineering, Faculty of Engineering, Shizuoka University,
関連論文
- Amorphous Dielectrics of Li_2O-Nb_2O_5 System : N: NONCRYSTAL MATERIALS
- Testing Method to Determine the Influence of Dust Adhesion on Digital Versatile Disk(Optics and Quantum Electronics)
- Removal of Adherent Waterdrops from Images Acquired with a Stereo Camera System(Stereo and Multiple View Analysis,Machine Vision Applications)
- ENVIRONMENT OBSERVATION BY STRUCTURE FROM MOTION WITH AN OMNI-DIRECTIONAL CAMERA(International Workshop on Advanced Image Technology 2006)
- Virtual wiper - removal of adherent noises from images of dynamic scenes by using a pan-tilt camera
- Region Extraction with Chromakey Using Stripe Backgrounds (Methodologies) (Machine Vision Applications)
- Chronic osteomyelitis of the tibia resembling benign bone tumors
- Accuracy Depending on Scanning Angle in Dynamic Spot Size Measurement Method for an Optical Disk Drive
- 液体急冷したAl-Li合金に関する研究
- Chroma Key Using a Checker Pattern Background(Advanced Image Technology)
- 3-D MAP GENERATION BY A MOBILE ROBOT EQUIPPED WITH A LASER RANGE FINDER(International Workshop on Advanced Image Technology 2006)
- Portal hemodynamic effects of sorafenib in patients with advanced hepatocellular carcinoma : a prospective cohort study
- Accuracy Depending on Scanning Angle in Dynamic Spot Size Measurement Method for an Optical Disk Drive