Effects of the Electrode Type on N100 and P300 in tDCS Applications
スポンサーリンク
概要
- 論文の詳細を見る
[Purpose] This study investigated the effects of types of electrode on N100 and P300 in transcranial direct current stimulation (tDCS) applications. [Subjects and Methods] Thirty subjects were randomly assigned to two groups with 15 subjects in each group depending on the electrode types. A positive electrode on the primary motor area (C4) and a negative electrode on the left primary motor area (C3), and stimulation was applied for 20 minutes. Before and after tDCS, N100 and P300 were measured by attaching an electrode to Fp1 and Fp2. [Results] In tDCS applications, N100 and P300 showed no significant interaction effects between time and group for either latency or amplitude in the Fp1 and Fp 2 areas, but there was a statistically significant difference in the main effect duration. [Conclusion] The latencies of N100 and P300 were shortened and that their amplitudes increased in both the Fp1 and Fp2 areas, regardless of the type of electrode.
- The Society of Physical Therapy Scienceの論文
著者
-
Lee Jeong-woo
Department Of Physical Therapy Kwang-ju Women's University
-
Yoon Se-won
Department Of Physical Therapy Kwang-ju Women's University
-
Park Woong-Sik
Department of Occupational Therapy, Kwangju Women's University, Republic of Korea
-
Heo Myoung
Department of Occupational Therapy, Gwangju University, Republic of Korea
-
Lee Dong-Geol
Department of Physical Therapy, Chungnam University Hospital, Republic of Korea
-
Jeong Seong-Kwan
Department of Physical Therapy, Seoul Orthopedic Medicine
-
Heo Myoung
Department of Occupational Therapy, College of Education, Health and Welfare, Kwangju University: 277 Hyodeok-Ro, Nam-Gu, Gwangju 503-703, Republic of Korea
関連論文
- Indetification of Symbiotic Arbuscular Mycorrhizal Fungi in Korea by Morphological and DNA Sequencing Features of Their Spores
- The Effects of Microcurrents on Inflammatory Reaction Induced by Ultraviolet Irradiation
- Change in Ankle Dorsiflexion Range of Motion and Ultrasonographic Images of the Tibialis Anterior with Age
- Ultrasonography Analysis of Knee Range of Motion and the Quadriceps Femoris of Patients with Knee Osteoarthritis
- Changes in Electrophysiologic Response during Repeated Contraction Training of the Tibialis Anterior
- A Study of Muscular Activities and Onset Times of the Tibialis Anterior and Medial Gastrocnemius Muscles of Elderly People in Climbing Stairs
- The Effect of Ankle Range of Motion on Balance Performance of Elderly People
- Concurrent Validity by Comparing EMG Activity between Manual Muscle Testing, Handheld Dynamometer, and Stationary Dynamometer in Testing of Maximal Isometric Quadriceps Contraction
- Effects of the Electrode Type on N100 and P300 in tDCS Applications