Morphological Evaluation of Proximal Anastomosis by PAS-Port® System in Patients with Long-Term Patent Grafts
スポンサーリンク
概要
- 論文の詳細を見る
Purpose: We examined grafts employing for morphological analysis of early and long-term results on proximal anastomosis with the PAS-Port®.Methods: One hundred and four patients treated by OPCAB with PAS-Port® were performed postoperative MDCT. Morphological evaluation of the proximal anastomotic region was classified into three groups (A; graft was anastomosed almost perpendicularly to the aortic wall, B; graft was same type A, but subsequently curved to form an acute angle with the aortic wall, C; graft take off acute angle with the aortic wall) evaluated on planar and sagittal sections.Results: One hundred twenty-six PAS-Port® were used. Patency rate was 99.0% at discharge, 94.7% at 1 year, and no blockages were detected thereafter in patients examined. The morphology rate was A 50.6%, B 15.3% and C 34.1% on planar sections, and A 58.8%, B 10.6% and C 30.6% on sagittal sections.Conclusion: The morphological evaluation of grafts revealed the degree of freedom in graft design to be relatively high and long-term patency posed no particular problem even if the layout of the proximal anastomotic region involved a relatively acute angle. The PAS-Port® was considered to be a highly reliable device which performed appropriate proximal anastomosis and improved the patency of vein grafting to the aortic wall.
- Annals of Thoracic and Cardiovascular Surgery 編集委員会の論文
著者
-
Hara Masanori
Department Of Applied Chemistry Graduate School Of Engineering Tohoku University
-
Fujii Takeshiro
Division Of Cardiovascular Surgery Department Of Surgery School Of Medicine Faculty Of Medicine Toho
-
Watanabe Yoshinori
Division Of Cardiovascular Surgery Department Of Surgery School Of Medicine Faculty Of Medicine Toho
-
Sasaki Yuki
Division Of Cardiovascular Surgery Department Of Surgery School Of Medicine Faculty Of Medicine Toho
-
KATAYANAGI TOMOYUKI
Division of Cardiovascular Surgery, Department of Surgery, School of Medicine, Faculty of Medicine,
-
Okuma Shinnosuke
Division of Cardiovascular Surgery, Toho University Medical Center Omori Hospital, Tokyo, Japan
-
Kawasaki Muneyasu
Department of Cardiovascular Surgery, Misato Central General Hospital, Misato, Saitama, Japan
関連論文
- 腎疾患および癌化学療法時に排出される糸球体上皮細胞の形態学的相違
- Study of coronary artery bypass using the PAS-Port device : assessment by multidetector computed tomography
- Usefulness of perioperative blood glucose control in patients undergoing off-pump coronary artery bypass grafting
- Limitations of Retrograde Continuous Tepid Blood Cardioplegia for Myocardial Remodeling
- Assessment of On-Pump Beating Coronary Artery Bypass Surgery Performed after Introduction of Off-Pump Approach
- Optimal Condition of Waveforms for Electrical Sterilization of Escherichia coli by HV Impulse
- Cell transplant or medical therapy to prevent heart failure?
- STMを用いた溶液中におけるイリジウム(III)電極上でのシアンの吸着構造解析
- Particle-initiated Breakdown Characteristics around Spacer under Lightning Impulse Voltage Superimposed on Pre-stressed DC
- Wire Particle Motion Behavior and Breakdown Characteristics around Different Shaped Spacers within Diverging Air Gap
- Wire Particle Motion Behavior and Breakdown Characteristics around Different Shaped Spacers within Diverging Air gap
- Electroreduction of Peroxide on Au(100) Surface Modified with Underpotentially Deposited Bismuth
- Partial Discharge Characteristics in an Artificial Air-filled Void under Superimposed Sinusoidal Voltages at LN_2 Temperature
- Reversible Electrical Breakdown of Bilayer Lipid Membranes with a Ramped Voltage and the Quantitative Analysis Based on a Transient Aqueous Pore Model
- An Aortic Root Pseudoaneurysm That Developed after Implantation of a Rectus Abdominis Muscle Flap to Treat an MRSA Mediastinitis : A Case Report
- 4 Influence and the Problems that DPC induction resulted in for Circulatory Disease(Symposium 17 (SY-17) (H) Comprehensive Economics in Clinical Cardiology : Current Status and Problems,Special Program,The 72nd Annual Scientific Meeting of the Japanese Ci
- Myocardial Electrode Implantation by the Subxiphoid Approach Using a Heart Stabilizer
- Successful Surgical Repair of an Infectious Thoracic Aortic Pseudoaneurysm Accompanied by Aortobronchopulmonary Fistula and Advanced Hepatic Dysfunction without Assisted Circulation
- A Case Report of Emergency Off-Pump CABG in an Aged Patient with ACS Renewing Ventricular Fibrillation
- Charging Mechanism and Behavior of a Conducting Particle on a Dielectrically Coated Electrode under Nonuniform DC and AC Electric Fields
- Stent Graft Implantation Combined with Coil Embolization and External-Internal Iliac Artery Bypass Surgery : Report of a Case
- Effect of Cryopreservation on Cell Proliferation and Immunogenicity of Transplanted Human Heart Cells
- Intravascular Ultrasound Imaging for Detection of Pseudoaneurysm with Aortobronchopulmonary Fistula after Graft Replacement of Descending Aorta
- The Variations in the Immunologic Features and Interleukin-6 Levels for the Surgical Treatment of Cardiac Myxomas
- Simultaneous Treatment of Washing, Disinfection and Sterilization Using Ultrasonic Levitation, Silver Electrolysis and Ozone Oxidation
- Improvement of Look-up Table Ray-Space Interpolation by Transforming Luminance and Slope(International Workshop on Advanced Image Technology 2005)
- Clinical significance of tubular and podocyte biomarkers in acute kidney injury
- 1-Alkenyl Group of Ethanolamine Plasmalogen Derives Mainly from De Novo-Synthesized Fatty Alcohol within Peroxisomes, but Not Extraperoxisomal Fatty Alcohol or Fatty Acdi
- Redo CABG for ACS via the Left Thoracotomy Using the PAS-Port System to the Descending Thoracic Aorta : A Case Report
- Fontan Conversion with Novel Direct Ablation After Childbirth : Report of a Case
- Optimal Culture Conditions for Constructing Durable Biografts for Repairing the Impaired Heart : Dynamic Cell Culture with Pre-seeding
- Severe intraglomerular detachment of podocytes in a Gitelman syndrome patient
- Replacement of Dynamic Cultured Biograft Improves Damaged Heart Function—Comparative Study of Static Cultured Biografts—
- Production of Carbon Nanoparticles Using Pulsed Arc Discharge Triggered by Dielectric Breakdown in Water
- Novel Infectious Agent-Free Hemostatic Material (TDM-621) in Cardiovascular Surgery
- Morphological Evaluation of Proximal Anastomosis by PAS-Port® System in Patients with Long-Term Patent Grafts