Fatigue resistance and retentive force of cast clasps treated by shot peening
スポンサーリンク
概要
- 論文の詳細を見る
Purpose: The fatigue failure of denture clasps has often been observed in removable partial denture rehabilitation. To increase their fatigue strength, shot peening was evaluated as a surface treatment. In this study, we evaluated the fatigue resistance and retention of cast clasps by using a shot peening treatment.Methods: A cobalt–chromium (Co–Cr) alloy, commercial pure titanium (CP Ti), silver–palladium–gold (Ag–Pd–Au), and a gold–platinum (Au–Pt) alloy were cast and then treated with shot peening. The retentive forces of the clasps were measured up to a repetition of 10,000 insertion/removal cycles in distilled water at 37 °C. A fatigue test was also performed using a 15-mm cantilever. Specimens were loaded with a constant deflection of 2.0 mm with 20 Hz. A shot peening treatment indicated a better stability of retentive forces than that without shot peening. The retentive force of Co–Cr clasps without shot peening was remarkably decreased at 500 cycles of insertion/removal repetition.Results: The clasps with a shot peening treatment provided approximately 1.4–3.6 times higher fatigue strengths than those without a shot peening treatment.Conclusion: To prevent the fatigue failure of the denture clasps and use the dentures for long term, a shot peening treatment would be recommended.
- 社団法人 日本補綴歯科学会の論文
社団法人 日本補綴歯科学会 | 論文
- 臼歯部人口歯排列に考慮を要した総義歯補綴の1症例 : 術後7年経過症例
- 無歯顎症例における水平的下顎位と側頭筋前方部の筋膨隆との関係に関する研究
- 口蓋裂患者に対して可撤性局部床義歯を用いた補綴処置の一症例
- 咬合異常が発症因子と考えられる顎関節症の治療
- クラウンの保持力に関する研究 : レジンモディファイドグラスアイオノマーセメントのサーマルサイクルによる検討