Pulse Infusion Thrombolysis (PIT) for Large Intracoronary Thrombus:Preventive Effect Against the `No Flow' Phenomenon in Revascularization Therapy for Acute Myocardial Infarction
スポンサーリンク
概要
- 論文の詳細を見る
Because large thrombus is a limitation for revascularization in acute myocardial infarction (AMI), the present study evaluated the effectiveness of pulse infusion thrombolysis (PIT) in patients with an AMI with a large (>15 mm) coronary thrombus, focusing on the occurrence of the `no flow' phenomenon. The retrospective study compared patients treated before (1988-95; Group A, n=74) and after (1996-99; Group B, n=40) the use of PIT, using the following parameters: lesion success (<50% stenosis during 30-min observation), procedural success (lesion success plus TIMI grade 3 flow), procedural no flow (TIMI grade 0 flow during the procedure with `back and forth movement' of contrast dye after lesion success), persistent no flow (consistent no flow without any flow improvement at the final visualization despite intensive treatment), reocclusion rate and in-hospital death. Group B was significantly better than Group A in procedural success (90% vs 66%; p=0.005), procedural `no flow' (51% vs 15%; p<0.001), and persistent `no flow' (34% vs 10%; p<0.05). Subgroup comparison was performed among the following groups: Direct-BA group (n=44): treated with mechanical angioplasty alone; ICT-BA group (n=40): treated with prior intracoronary thrombolysis and angioplasty; and PIT-BA group (n=30): treated with PIT and angioplasty. There were no differences in thrombus length and lesion success among these 3 groups. Procedural success was best achieved in PIT-BA: 97% vs 52% for Direct-BA (p=0.003) and 68% for ICT-BA (p=0.009). Procedural `no flow' was least in PIT-BA: 50% vs 3.3% for Direct-BA (p=0.003) and 25% vs 3.3% for ICT-BA (p=0.042). Persistent `no flow' was less frequent in PIT-BA than Direct-BA: 32% vs 3.3% (p=0.009). However, the difference between ICT-BA and Direct-BA was insignificant: 13% vs 3.3% (p=0.53). There were no differences in reocclusion rate and in-hospital death among the 3 subgroups. And there were no differences between Direct-BA and ICT-BA in any parameters. PIT was effective in preventing `no flow' in the mechanical revasculalization for AMI especially those cases with a large thrombus. (Jpn Circ J 2001; 65: 94 - 98)
- 社団法人 日本循環器学会の論文
社団法人 日本循環器学会 | 論文
- Adenosine Triphosphate Exposes Dormant Pulmonary Vein Conduction Responsible for Recurrent Atrial Tachyarrhythmias : Importance of Evaluating the Dormant Conduction During the Re-Do Ablation Procedure
- Impact of Diabetes Mellitus on Rehospitalization for Heart Failure Among Survivors of Acute Myocardial Infarction in the Percutaneous Coronary Intervention Era
- N-Acetylcysteine Reduces the Severity of Atherosclerosis in Apolipoprotein E-Deficient Mice by Reducing Superoxide Production
- Incremental Effects of Eicosapentaenoic Acid on Cardiovascular Events in Statin-Treated Patients With Coronary Artery Disease : Secondary Prevention Analysis From JELIS
- Risk of Smoking and Metabolic Syndrome for Incidence of Cardiovascular Disease : Comparison of Relative Contribution in Urban Japanese Population : The Suita Study