Dispersion of lodine (<SUP>125</SUP>I) and Trapping of Dispersed <SUP>125</SUP>I by Charcoal Cartridges
スポンサーリンク
概要
- 論文の詳細を見る
<I>The dispersal rates of</I> <SUP>125</SUP>I <I>defined here as a dispersed activity in Bq per hour divided by the total activity contained in a solution, and the collection efficiency of dispersed</I> <SUP>125</SUP>I <I>by charcoal cartridges were measured under the various pH conditions in the solution.</I><BR><I>The values of dispersal rate observed under working conditions in common biochemical procedures were (3.74±1.19) ×10</I><SUP>-4</SUP> (<I>h</I><SUP>-1</SUP>), (<I>4.27±1.90</I>) ×<I>10</I><SUP>-4</SUP> (<I>h</I><SUP>-1</SUP>) and (<I>6.31±2.05</I>) ×<I>10</I><SUP>-4</SUP> (<I>h</I><SUP>-1</SUP>) <I>for alkaline, neutral and acidic conditions of the solution, respectively. And those values obtained by the evaporation of solution to dryness were elevated more than 100 to 1000 times independent of pH of the solution. Under the case of common biochemical procedures, nearly 90% of the dispersed</I> <SUP>125</SUP>I <I>was trapped on the 1st charcoal cartridge which was inserted between dispersal part and exhaust part. No</I> <SUP>125</SUP>I <I>was detected in the following 2nd and 3rd charcoal cartridges.</I>
- 社団法人 日本アイソトープ協会の論文
社団法人 日本アイソトープ協会 | 論文
- Distortion of Pulse Height Spectra Due to Absorbers in the Measurement of Low-energy .BETA.-rays with a Silicon Detector.
- タイトル無し
- Estimation of Angular Distributions of the Low-Energy .BETA.-Ray Emission from a Sealed Source.
- Comparison of SPECT images with four kinds of 99nTc collimators.
- Cross Talks on to 201Tl- and 123I-Photopeak Windows with Simultaneous Administration of Them, Using of a Gamma Camera.