<I>Fundamental and clinical investigation on the liver scanning were carried out with</I><SUP>99<I>m</I></SUP>Tc-Sn-<I>colloid</I> (<SUP>99<I>m</I></SUP>Tc-Sn-<I>C</I>) <I>and</I> <SUP>99<I>m</I></SUP>Tc-<I>phytate</I> (<SUP>99<I>m</I></SUP>Tc-<I>P</I>), <I>both of which were made into kits by Daiichi Radioisotope Labs., Ltd. for the non-electrolytic method.</I><BR><I>In the preparing point of view, </I><SUP>99<I>m</I></SUP>Tc-<I>P seems to be prepared more simple and stable than</I><SUP>99<I>m</I></SUP>Tc-Sn-<I>C. The labelling yields of both agents were about 99% and, also their particle sizes were uniform. In the liver scintigrams, any remarkable differences between both agents were not observed in shape, size, and RI distribution of the liver and any background images disturbing to read the scintigrams were not observed.</I><BR><I>The splenic image with</I><SUP>99<I>m</I></SUP>Tc-Sn-<I>C was more clearly delineated than that with</I><SUP>99<I>m</I></SUP>Tc-<I>P. Generally, the RI ratio of spleen vs. liver (right lobe) (Sp/R) with</I><SUP>99<I>m</I></SUP>Tc-Sn-<I>C was greater than that with</I><SUP>99<I>m</I></SUP>Tc-<I>P irrespective of each group of liver diseases. Especially, in the liver cirrhosis, Sp/R ratio was remarkably high, and this fact is very important for its scan diagnosis. In the liver scintigrams, the degree of splenic visualization with</I><SUP>99<I>m</I></SUP>Tc-<I>P being quite similar to that with</I><SUP>198</SUP>Au-<I>colloid, the scintigram with</I><SUP>99<I>m</I></SUP>Tc-<I>P seems convenient as diagnostic criteria.</I><BR><I>In the point of correct diagnosis for liver cirrhosis, </I><SUP>99<I>m</I></SUP>Tc-Sn-<I>C was superior to</I><SUP>99<I>m</I></SUP>Tc-<I>P</I>.<BR><I>Liver scintigrams obtained with</I><SUP>99<I>m</I></SUP>Tc-Sn-<I>C and</I><SUP>99<I>m</I></SUP>Tc-<I>P respectively are useful for the differential diagnosis of the upper abdominal masses, observation of therapeutic course of various liver diseases, decision on the existence of operative indication and its method. No side effects were observed in both agents, </I><SUP>99<I>m</I></SUP>Tc-Sn-<I>C and</I><SUP>99<I>m</I></SUP>Tc-<I>P</I>.<BR><I>We came to a conclusion that both</I><SUP>99<I>m</I></SUP>Tc-Sn-<I>C and</I><SUP>99<I>m</I></SUP>Tc-<I>P are effective scanning agents, giving scintigrams of excellent quality with very little internal radiation exposure and fairly simple kit operation.</I>
- 社団法人 日本アイソトープ協会の論文
社団法人 日本アイソトープ協会 | 論文
- Distortion of Pulse Height Spectra Due to Absorbers in the Measurement of Low-energy .BETA.-rays with a Silicon Detector.
- タイトル無し
- Estimation of Angular Distributions of the Low-Energy .BETA.-Ray Emission from a Sealed Source.
- Comparison of SPECT images with four kinds of 99nTc collimators.
- Cross Talks on to 201Tl- and 123I-Photopeak Windows with Simultaneous Administration of Them, Using of a Gamma Camera.